4200 FlexScan Series

The 4200 FlexScan is a hand-held FTIR specifically designed for multiple surface analysis applications.

Notify me on updates of this product 

Availability: DISCONTINUED

Heidi Kijenski
Clinical Marketing Director
Heidi.Kijenski@agilent.com
+1 800 227 9770
5301 Stevens Creek Boulevard
Santa Clara, CA 95051
USA
John Corbett
john.corbett@agilent.com
www.agilent.com
Manufacturer
Agilent Technologies
Product Name
4200 FlexScan Series
Detection Category
Chemical; Explosives
Detection Principle
Molecular Spectroscopy;
Detection Method
Mid-infrared Spectroscopy;
Application
Emergency Response; Screening; Bulk Analysis;
Equipment Type
Instrument
Product Synopsis
The 4200 FlexScan is a hand-held FTIR specifically designed for multiple surface analysis applications.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
5.00 x 2.94 × 0.81 in (127 × 74.60 × 20.6 mm)
Weight
<1 lb.; 6.3 oz (178.60 g)
Power Requirements
Lithium Battery; Rechargeable (> 8 hours)
Noise Produced
None
Transportability
Handheld
Ruggedness
None; Not militarized, drop sensitive
Operating Conditions
0 to 50°C (32 to 120°F); 0 to 95% RH, non-condensing
Consumables
None
Calibration Schedule
Performance check prior to each use
Communications Interface
Wireless LAN IEEE® 802.11 b/g Antenna: Internal Bluetooth v2.0 +EDR Class 2 Supported
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$38,000.00
Tested For Chemical Agents
Amenable based on technology
Tested For ITF-25 TIC/TIMs
Amenable based on technology
Tested For Explosives
Amenable based on technology
Tested For Narcotics
Amenable based on technology
Other Chemical Targets
Infrared-active compounds
Sample Introduction
Solid; Liquid
Sensitivity/Detection Limits
Bulk; mg; g
Known Interferents/Inhibitors
Successful identification of an unknown is dependent on the presence of the corresponding reference spectrum in the library. Analysis of mixtures can produce erroneous search results unless the library contains a reference spectrum of the mixture itself.
False Positive Rates
<1%
False Negative Rates
<1%
Start Up Time (From Cold Start To Sample Ready)
5 minutes
Response Time (Sample Application To Output)
<5 minutes; <3 minutes
Software Control
Software add-on package available for saving sample and file information
Other Operational Parameters
Multiple sample interfaces available: diffuse reflectance, external reflectance, grazing angle, ATR; Michelson interferometer with 4 cm–1 resolution; Frequency range: 650 to 4,000 cm–1
Training Required
<1 day training
Manuals Available
Yes
IATA Shipping Restrictions
Yes;Li-ion battery
Please enter contact info.
Email Address: 
Company: 
Name: 