4200 FlexScan Series
The 4200 FlexScan is a hand-held FTIR specifically designed for multiple surface analysis applications.
Availability: DISCONTINUED
| Manufacturer |
| Agilent Technologies |
| Product Name |
| 4200 FlexScan Series |
| Detection Category |
| Chemical; Explosives |
| Detection Principle |
| Molecular Spectroscopy; |
| Detection Method |
| Mid-infrared Spectroscopy; |
| Application |
| Emergency Response; Screening; Bulk Analysis; |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The 4200 FlexScan is a hand-held FTIR specifically designed for multiple surface analysis applications. |
| Availability |
| DISCONTINUED |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 5.00 x 2.94 × 0.81 in (127 × 74.60 × 20.6 mm) |
| Weight |
| <1 lb.; 6.3 oz (178.60 g) |
| Power Requirements |
| Lithium Battery; Rechargeable (> 8 hours) |
| Noise Produced |
| None |
| Transportability |
| Handheld |
| Ruggedness |
| None; Not militarized, drop sensitive |
| Operating Conditions |
| 0 to 50°C (32 to 120°F); 0 to 95% RH, non-condensing |
| Consumables |
| None |
| Calibration Schedule |
| Performance check prior to each use |
| Communications Interface |
| Wireless LAN IEEE® 802.11 b/g Antenna: Internal Bluetooth v2.0 +EDR Class 2 Supported |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| >5 years |
| Unit Cost |
| $38,000.00 |
| Tested For Chemical Agents |
| Amenable based on technology |
| Tested For ITF-25 TIC/TIMs |
| Amenable based on technology |
| Tested For Explosives |
| Amenable based on technology |
| Tested For Narcotics |
| Amenable based on technology |
| Other Chemical Targets |
| Infrared-active compounds |
| Sample Introduction |
| Solid; Liquid |
| Sensitivity/Detection Limits |
| Bulk; mg; g |
| Known Interferents/Inhibitors |
| Successful identification of an unknown is dependent on the presence of the corresponding reference spectrum in the library. Analysis of mixtures can produce erroneous search results unless the library contains a reference spectrum of the mixture itself. |
| False Positive Rates |
| <1% |
| False Negative Rates |
| <1% |
| Start Up Time (From Cold Start To Sample Ready) |
| 5 minutes |
| Response Time (Sample Application To Output) |
| <5 minutes; <3 minutes |
| Software Control |
| Software add-on package available for saving sample and file information |
| Other Operational Parameters |
| Multiple sample interfaces available: diffuse reflectance, external reflectance, grazing angle, ATR; Michelson interferometer with 4 cm–1 resolution; Frequency range: 650 to 4,000 cm–1 |
| Training Required |
| <1 day training |
| Manuals Available |
| Yes |
| IATA Shipping Restrictions |
| Yes;Li-ion battery |