5975T GC/MSD

The Agilent 5975T LTM GC/MSD is a transportable GC/MSD system that delivers the same performance, reliability and quality results as a bench top. Agilent’s proprietary LTM technology is used for faster GC analysis by providing dramatically faster temperature ramp rates (up to 1200°C/minute). DRS and RTL databases are leveraged for faster screening and analysis of compounds in the field. The 5975T incorporates an anti-vibration base for safer transport.

Notify me on updates of this product 

Availability: DISCONTINUED

+1 816 427 5510
5301 Stevens Creek Boulevard
Santa Clara, CA 95051
USA
www.agilent.com
Manufacturer
Agilent Technologies
Product Name
5975T GC/MSD
Detection Category
Chemical; Explosives
Detection Principle
Spectrometry; Chromatography;
Detection Method
Quadrupole Mass Spectrometry;
Application
Laboratory Analysis; Trace Analysis;
Equipment Type
Instrument
Product Synopsis
The Agilent 5975T LTM GC/MSD is a transportable GC/MSD system that delivers the same performance, reliability and quality results as a bench top. Agilent’s proprietary LTM technology is used for faster GC analysis by providing dramatically faster temperature ramp rates (up to 1200°C/minute). DRS and RTL databases are leveraged for faster screening and analysis of compounds in the field. The 5975T incorporates an anti-vibration base for safer transport.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
User Feedback Sources
Hands-on experience
Dimensions
26 x 24 x 19 in (650 x 610 x 490 mm)
Weight
>50 lbs.; 125 or 150 lb (57 or 68 kg), depending on configuration
Power Requirements
AC/DC Line Power; 120 V AC
Noise Produced
None
Transportability
Benchtop/Fixed; Small Footprint
Ruggedness
None
Operating Conditions
10 to 40°C (50 to 105°F); 40 to 80% RH
Consumables
>$1,000/year; Chromatography supplies (ferrules, GC columns, nuts, carrier gas, etc.). Mass spectrometry supplies (forepump oil, filaments, gaskets, O-rings, etc.)
Solvents/Reagents
None
Calibration Schedule
Yes
Suggested Routine Maintenance
Typical for benchtop GC/MS system—replace filament, change roughing pump oil
Shelf Life
>5 years
Unit Cost
$100,000.00
Maintenance Cost
$3,000/year
Tested For Chemical Agents
Amenable based on technology
Tested For ITF-25 TIC/TIMs
Amenable based on technology
Tested For Explosives
Amenable based on technology
Tested For Narcotics
Amenable based on technology
Other Chemical Targets
Applicable to all organic compounds amenable to GC
Adaptability
Yes; user can add new targets in the field
Sample Introduction
Liquid; Vapor/Gas
Sensitivity/Detection Limits
ng
Known Interferents/Inhibitors
GC/MS is highly selective for volatile and semivolatile organic compounds when used by a skilled operator. Low false positive/negative rates for target analytes. False IDs are more likely for unknowns (nontargets) since GC retention times cannot be compared to reference RTs.
False Positive Rates
<1%
False Negative Rates
<1%
Start Up Time (From Cold Start To Sample Ready)
4 hours
Response Time (Sample Application To Output)
>15 minutes; 5 to 45 minutes
Alarm Capability
Audible and visual
Software Control
Desktop computer
Training Required
>1 week training
Training Available
1 to 2 weeks training recommended. On-going training recommended
Manuals Available
Operator's manual
Warranties
1 year (extended warranties available)