6850 Series II Network GC
The 6580 is a small GC for laboratories where bench space, ease of use, and independent channel flexibility are important.
Availability: Commercially Available
+1 816 427 5510
5301 Stevens Creek Boulevard
Santa Clara, CA 95051
USA
|
|
www.agilent.com
Manufacturer |
| Agilent Technologies |
Product Name |
| 6850 Series II Network GC |
Detection Category |
| Chemical; Explosives |
Detection Principle |
| Spectrometry; Chromatography; |
Detection Method |
| Gas Chromatography; Quadrupole Mass Spectrometry; Flame Photometric Detection (FPD); Flame Ionization Detection (FID); |
Application |
| Laboratory Analysis; Trace Analysis; |
Equipment Type |
| Instrument |
Product Synopsis |
| The 6580 is a small GC for laboratories where bench space, ease of use, and independent channel flexibility are important. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 20 x 11 x 22 in (508 x 280 x 560 mm), 20 x 24 x 22 in (508 x 610 x 560 mm) with 5975 MSD |
Weight |
| >50 lbs.; 64 lbs (29 kg) |
Power Requirements |
| AC/DC Line Power; 110 V AC, 1.4 to 2 A |
Noise Produced |
| None |
Transportability |
| Benchtop/Fixed |
Ruggedness |
| None |
Operating Conditions |
| 4 to 43°C (40 to 110°F). Not designed for harsh environments |
Consumables |
| >$1,000/year; Typical for GC (helium carrier gas, GC columns, ferrules, injection port liners, chemical standards, etc.) |
Calibration Schedule |
| Calibration required for each target chemical to determine GC retention time and detector response. |
Suggested Routine Maintenance |
| Typical for GC |
Available Accessories |
| Optional thermal desorption unit, detectors |
Communications Interface |
| Windows 2000-based PC data acquisition system provides capability for numerous communications options. |
Shelf Life |
| >5 years; Product lifetime indefinite with routine maintenance. Serviceability for ten years |
Unit Cost |
| $15,000.00 |
Tested For Chemical Agents |
| Amenable based on technology |
Tested For ITF-25 TIC/TIMs |
| Amenable based on technology |
Tested For Explosives |
| Amenable based on technology |
Tested For Narcotics |
| Amenable based on technology |
Other Chemical Targets |
| Currently used in a number of mobile labs, government/military; used in areas to facilitate CWA demilitarization projects. Special version with FPD optimized for CWAs. |
Adaptability |
| Yes; user can add new targets in the field |
Sample Introduction |
| Liquid |
Sensitivity/Detection Limits |
| % |
Known Interferents/Inhibitors |
| Tested for electrical and other environmental interferences |
False Positive Rates |
| <1% |
False Negative Rates |
| <1% |
Start Up Time (From Cold Start To Sample Ready) |
| 1 to 2 hours for internal heaters to reach operating temperatures |
Response Time (Sample Application To Output) |
| >15 minutes; 2 to 30 minutes typical response time, depending on analyte and GC method |
Alarm Capability |
| Audible and visual |
Software Control |
| Chemstation and Easychrome |
Training Required |
| >1 week training |
Training Available |
| On-site and off-site training available from vendor |
Manuals Available |
| Operator’s Manual |
Warranties |
| 1 year factory warranty. 3 year extended warranty and service contract are available at additional cost. Up to 5 year service contracts are also available. |
IATA Shipping Restrictions |
| Yes; Compressed gas cylinders must be shipped ground only according to IATA regulations. |