ACEM 9350
The ACEM 9350 Captures compounds of interest on adsorbent material packed in glass cartridges and then introduce the chemicals into a GC system. The CDS 9350 is the latest real time air monitoring system. It has been designed to deal with the more difficult environments that have to date, not been achievable. This includes the ability to collect and analyze compounds with boiling points down to -50º C, without cryogen trapping or cryofocusing, and collect analytes with boiling points above 300º C with a sampling line and all heated zones capable of maintaining temperatures of up to 350º C.
The CDS 9350 has fast flow capabilities for sample collection of up to 1.5 LPM, rapid heat and cool down times for both sorbent tubes and focus trap without the need for cryo focusing. This allows for much quicker cycle times, from collection to completion of analytical analysis, when utilizing the latest in Low Thermal Mass (LTM) chromatography techniques.
Availability: Commercially Available
Manufacturer |
| CDS Analytical, Inc. |
Product Name |
| ACEM 9350 |
Detection Category |
| Chemical; Explosives |
Detection Principle |
| Chromatography; |
Detection Method |
| Gas Chromatography; Flame Photometric Detection (FPD); |
Application |
| Laboratory Analysis; Trace Analysis; Gas Analysis; |
Equipment Type |
| Instrument |
Product Synopsis |
| The ACEM 9350 Captures compounds of interest on adsorbent material packed in glass cartridges and then introduce the chemicals into a GC system. The CDS 9350 is the latest real time air monitoring system. It has been designed to deal with the more difficult environments that have to date, not been achievable. This includes the ability to collect and analyze compounds with boiling points down to -50º C, without cryogen trapping or cryofocusing, and collect analytes with boiling points above 300º C with a sampling line and all heated zones capable of maintaining temperatures of up to 350º C.
The CDS 9350 has fast flow capabilities for sample collection of up to 1.5 LPM, rapid heat and cool down times for both sorbent tubes and focus trap without the need for cryo focusing. This allows for much quicker cycle times, from collection to completion of analytical analysis, when utilizing the latest in Low Thermal Mass (LTM) chromatography techniques.
|
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 10.5 x 9.25 x 12.5 in (267 x 235 x 317.5 mm) |
Weight |
| <50 lbs.; (22.7 kg) |
Power Requirements |
| AC/DC Line Power; 120 V AC |
Transportability |
| Benchtop/Fixed |
Operating Conditions |
| Designed for use in a controlled environment 59° to 95°F. |
Consumables |
| <$1,000/year; Sorbent materials |
Suggested Routine Maintenance |
| Minimal |
Communications Interface |
| Wireless LAN interface with ChemStation allows for remote operation |
Shelf Life |
| >5 years; Product lifetime indefinite with routine maintenance |
Unit Cost |
| $25,000.00 |
Maintenance Cost |
| $1,000 - $2,000 per year |
Tested For Chemical Agents |
| GA, GB, GD, GF, VX, HD, HN, L tested on similar MSD systems. Other CWA also tested |
Tested For ITF-25 TIC/TIMs |
| Most organic compounds |
Tested For Explosives |
| Most organic compounds |
Other Chemical Targets |
| Applicable to all organic compounds amenable to GC |
Adaptability |
| Yes |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| ppt |
Known Interferents/Inhibitors |
| GC/MS is a highly selective technique for identification of organic compounds when used by a skilled operator, with low false positive/negative rates for target analytes. False IDs are more likely for unknowns (non-targets) since GC retention times cannot be compared to reference RTs. Additional selectivity for CWAs provided by FPD detector (sensitive to P and S only). |
Start Up Time (From Cold Start To Sample Ready) |
| 30 minutes |
Response Time (Sample Application To Output) |
| >15 minutes; 5-45 minutes |
Alarm Capability |
| Visual |
Software Control |
| Agilent ChemStation data acquisition software |
Other Operational Parameters |
| Entire system is mounted on a steel plate for moving from a fixed laboratory to a mobile platform. Entire sample pathway is closed; no effluent gases can escape from any components into the atmosphere during analysis. |
Training Required |
| <1 day training |
Training Available |
| Yes |
Manuals Available |
| Operator’s manual on CD |