Eagle
ChemImage closed business in April 2023.
DISCONTINUED - Eagle combines microscopic examination, Raman spectroscopy and fluorescence spectroscopy for rapid identification of chemical and biological threats.
Availability: DISCONTINUED
Tracy Vogt
Ext 232
(412) 241-7335
7301 Penn Avenue
Pittsburgh, PA 15208
|
|
www.chemimage.com
Manufacturer |
| ChemImage Sensor Systems (HISTORICAL) |
Product Name |
| Eagle |
Detection Category |
| Chemical; Biological; Explosives; |
Detection Principle |
| Molecular Spectroscopy; |
Detection Method |
| Raman Spectroscopy; |
Application |
| Laboratory Analysis; Bulk Analysis; Screening; |
Equipment Type |
| Instrument |
Product Synopsis |
| ChemImage closed business in April 2023.
DISCONTINUED - Eagle combines microscopic examination, Raman spectroscopy and fluorescence spectroscopy for rapid identification of chemical and biological threats. |
Availability |
| DISCONTINUED |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 21 x 24.5 x 26.5 in (53.3 x 62.2 x 67.3 cm) |
Weight |
| >50 lbs.; 127 lbs (57.6 kg) |
Power Requirements |
| AC/DC Line Power; 110/220 V AC, 50/60 Hz, 700 watts max. |
Transportability |
| Person-Portable |
Ruggedness |
| Vibration/Shock; Drop sensitive, but can withstand normal transportation |
Operating Conditions |
| 0 to 40°C (32 to 105°F) |
Consumables |
| <$1,000/year; Requires aluminum coated microscope slides, supplied by the manufacturer. DI water to disperse the sample. |
Calibration Schedule |
| Daily by the user |
Suggested Routine Maintenance |
| Mercury arc lamp (source) has a 280 hr operating life |
Data Analysis Support Equipment |
| Computer |
Communications Interface |
| USB and a video cable |
Tested For Chemical Agents |
| Yes |
Tested For ITF-25 TIC/TIMs |
| Yes |
Tested For Explosives |
| Yes |
Other Chemical Targets |
| Yes, can detect biologicals |
Sample Introduction |
| Solid; Liquid |
Start Up Time (From Cold Start To Sample Ready) |
| 10 to 15 minutes at room temperature, longer at higher temperatures. |
Response Time (Sample Application To Output) |
| >15 minutes; < 20 minutes |
Alarm Capability |
| Visual results |
Software Control |
| Yes |
Other Operational Parameters |
| When spores are located, 20 spores of bacteria can produce results. |
Training Required |
| <1 day training |
Training Available |
| Yes. 1 day training for installation and operation. |
Manuals Available |
| Operator’s manual |
Warranties |
| 1 year |
IATA Shipping Restrictions |
| No |