LightGuard

ChemImage closed business in April 2023. DISCONTINUED - The LightGuard™ wide area surveillance capability is enabled by a user interface with a real-time display to alert users of a potential threat and type. The system allows users to develop a signature library by using reference samples to store materials of interest for explosives, chemical threats and illicit drug substances. Library updates in the field are made quick and easy for detection of new materials. The product allows for standoff distances of 7 to 50 m.

Notify me on updates of this product 

Availability: DISCONTINUED

Steven Mitts
mittss@chemimage.com
+1 503 332 5452
7301 Penn Avenue
Pittsburgh, PA 15208
USA
www.aperio.com
Manufacturer
ChemImage Sensor Systems (HISTORICAL)
Product Name
LightGuard
Detection Category
Chemical; Explosives;
Detection Principle
Molecular Spectroscopy;
Detection Method
Hyperspectral Imaging;
Application
Bulk Analysis; Screening; Emergency Response;
Equipment Type
Instrument
Product Synopsis
ChemImage closed business in April 2023. DISCONTINUED - The LightGuard™ wide area surveillance capability is enabled by a user interface with a real-time display to alert users of a potential threat and type. The system allows users to develop a signature library by using reference samples to store materials of interest for explosives, chemical threats and illicit drug substances. Library updates in the field are made quick and easy for detection of new materials. The product allows for standoff distances of 7 to 50 m.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
20 x 12 x 12 in (49 x 30 x 30 cm)
Weight
<30 lbs.; 10 lbs (4.5 kg)
Power Requirements
Lithium Battery
Transportability
Person-Portable
Ruggedness
None
Operating Conditions
Outdoor use
Consumables
None
Suggested Routine Maintenance
Minimal
Data Analysis Support Equipment
Laptop
Communications Interface
Wi-Fi
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$250,000.00
Maintenance Cost
Minimal
Tested For Chemical Agents
Yes
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
Yes
Tested For Narcotics
Yes
Other Chemical Targets
Yes
Sample Introduction
Liquid;Solid;Vapor/Gas;
Start Up Time (From Cold Start To Sample Ready)
< 30 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds); 2 to 10 seconds
Total Run Time
Minutes
Alarm Capability
Audible and visual
Software Control
PC
Training Required
<1 day training
Training Available
Yes
Manuals Available
Operator Manual
Warranties
1 year, extended available
ITAR/EAR Export Regulations
Yes; ITAR regulations may apply
IATA Shipping Restrictions
Yes; Lithium ion battery
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: