FROG-4000
Defiant Technologies’ FROG-4000 is a hand held system for detection of volatile organic compounds in water, air, and soil. The system incorporates a micro preconcentrator that is coated with a nanoporous material. The micro preconcentrator has an integrated heater for thermal desorption. The micro GC separates target analytes and also has an integrated heater for temperature ramp chromatography. The detector is a miniature PID (10.6 eV). Chemical name and concentration can be viewed on FROG-4000’s LCD display, or the user may watch the chromatogram real time on a computer.
Availability: DISCONTINUED
Manufacturer |
| Defiant Technologies |
Product Name |
| FROG-4000 |
Detection Category |
| Chemical |
Detection Principle |
| Sensors;Chromatography; |
Detection Method |
| Photoionization Detection;Gas Chromatography; |
Application |
| Emergency Response; Gas Analysis; |
Equipment Type |
| Instrument |
Product Synopsis |
| Defiant Technologies’ FROG-4000 is a hand held system for detection of volatile organic compounds in water, air, and soil. The system incorporates a micro preconcentrator that is coated with a nanoporous material. The micro preconcentrator has an integrated heater for thermal desorption. The micro GC separates target analytes and also has an integrated heater for temperature ramp chromatography. The detector is a miniature PID (10.6 eV). Chemical name and concentration can be viewed on FROG-4000’s LCD display, or the user may watch the chromatogram real time on a computer. |
Availability |
| DISCONTINUED |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 10 x 7.5 x 14.5 in (254 x 191 x 369 mm) |
Weight |
| <5 lbs.; 4.8 lbs. (2.2 kg) |
Power Requirements |
| NiMH Battery; AC/DC Line Power; Rechargeable NiMH 5000 mAhr battery External 9V, 3A power supply (6 hours) |
Transportability |
| Handheld |
Ruggedness |
| None |
Consumables |
| <$1,000/year; Purge tube |
Calibration Schedule |
| Yes |
Data Analysis Support Equipment |
| PC, SD card |
Communications Interface |
| RS-232, USB |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Unit Cost |
| $25,000.00 |
Other Chemical Targets |
| MTBE/BTEX, TCE/PCE Alcohols/Ketones Naphthalene and other VOCs |
Adaptability |
| Yes; user can add new targets to detector with support |
Sample Introduction |
| Liquid; Vapor/Gas; Solid |
Sensitivity/Detection Limits |
| µg |
Response Time (Sample Application To Output) |
| <5 minutes |
Software Control |
| Yes |
Training Required |
| <1 day training |
Training Available |
| Yes |
Manuals Available |
| Yes |
IATA Shipping Restrictions |
| Yes; Carrier gas |