Model IR-700-CH Combustible Gas Sensor

Detcon Model IR-700-CH is a non-intrusive “Smart” sensor designed to detect and monitor combustible hydrocarbon gases in air over the range of 0-100% LEL using miniature non-dispersive Infrared Optical (NDIR) sensor technology. As compared to catalytic bead sensors, with NDIR there is no risk of sensor poisoning, no risk of high concentration saturation, and no need for O2 to be present. The plug-in, field replaceable detector features over-sized gold-plated connections that help prevent corrosion.

Notify me on updates of this product 

Availability: Commercially Available

James Alpha
Vice President of Operations
jamesalpha@tyco.com
+1 888 367 4286
4055 Technology Forest Boulevard
The Woodlands, TX 77381
USA
www.detcon.com
Manufacturer
Detcon, Inc.
Product Name
Model IR-700-CH Combustible Gas Sensor
Detection Category
Chemical
Detection Principle
Molecular Spectroscopy;
Detection Method
Non-Dispersive Infrared (NDIR); Infrared (IR) Spectroscopy ;
Application
Gas Analysis;
Equipment Type
Sensor
Product Synopsis
Detcon Model IR-700-CH is a non-intrusive “Smart” sensor designed to detect and monitor combustible hydrocarbon gases in air over the range of 0-100% LEL using miniature non-dispersive Infrared Optical (NDIR) sensor technology. As compared to catalytic bead sensors, with NDIR there is no risk of sensor poisoning, no risk of high concentration saturation, and no need for O2 to be present. The plug-in, field replaceable detector features over-sized gold-plated connections that help prevent corrosion.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
7 x 2.2 in (178 x 56 mm)
Weight
<5 lbs.; 2 lbs (0.907kg) (sensor only)
Power Requirements
AC/DC Line Power; 11 to 30 VDC, Consumption 68 mA (<1.7 W, normal operation), 85 mA (2 W, maximum)
Transportability
Pocket Size
Ruggedness
Extreme Temperatures/Humidity
Operating Conditions
-40 to 75°C(-40 to 167°F); 0 to 99% RH, non-condensing
Solvents/Reagents
None
Calibration Schedule
Yes
Suggested Routine Maintenance
Minimal
Available Accessories
Remote Alarm Module (Remote Operation and 2 Alarm Relays plus Fault), Hart Integration Module (Hart Communication Protocol version 7.0, HART Registered), Profibus Integration Module (Certified to Profibus DP Standard), Foundation Fieldbus Integration Module (Foundation Fieldbus version 5.01) Wireless Integration Module (Detcon Model RXT-320, SmartWireless® Transceivers)
Communications Interface
4-20 mA DC, RS-485 MODBUS-RTU and wireless
Shelf Life
>5 years
Unit Cost
$1,345.00
Maintenance Cost
Minimal
Other Chemical Targets
Combustible Hydrocarbons
Adaptability
No; cannot detect or add new targets
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
%; %LEL
Response Time (Sample Application To Output)
Continuous (<30 seconds); T50: < 6 seconds, T90: < 30 seconds
Alarm Capability
Yes
Software Control
Yes
Training Required
<1 week training
Manuals Available
Operator’s Manual
Warranties
Plug in detector 2 years, Transmitter 2 years
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: