Civil Defense Simultest (CDS) Kit

Two simultaneous Test Sets measure chemical substances including nerve, blood, lung, and blister agents. Five air sampling tubes per Test Set. Test Set 1 includes tubes to test for: thioethers, phosgene, HCN, arsenic/arsine, basic nitrogen compounds. Test Set 2 includes tubes to test for: cyanogen chloride, thioethers, phosgene, chlorine, phosphonate esters.

Notify me on updates of this product 

Availability: DISCONTINUED

+1 800 437 2437
7256 South Sam Houston Parkway, Suite 100
Houston, TX 77085
USA
+49 451 8820
Moislinger Allee 53-55
23558 Lübeck
Germany
www.draeger.com
Manufacturer
Dräger Safety, Inc.
Product Name
Civil Defense Simultest (CDS) Kit
Detection Category
Chemical; Explosives
Detection Principle
Colorimetric
Detection Method
Colorimetric
Application
Emergency Response; Screening; Bulk Analysis; Trace Analysis;
Equipment Type
Instrument
Product Synopsis
Two simultaneous Test Sets measure chemical substances including nerve, blood, lung, and blister agents. Five air sampling tubes per Test Set. Test Set 1 includes tubes to test for: thioethers, phosgene, HCN, arsenic/arsine, basic nitrogen compounds. Test Set 2 includes tubes to test for: cyanogen chloride, thioethers, phosgene, chlorine, phosphonate esters.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
19.25 × 15.5 × 7.5 in (489 x 394 x 191 mm)
Weight
<30 Lbs.; Tubes: < 1 Lbs. (0.45 kg) ; Kit: 15 Lbs. (6.8 kg)
Power Requirements
None
Noise Produced
Not specified; hand pump produces moderate noise
Transportability
Handheld
Operating Conditions
May be used in most environmental conditions. Avoid extreme heat.
Consumables
<$1,000/year; dependent on use. CDS Test Sets. Detector tubes are single-use only.
Solvents/Reagents
Colorimetric reagents on solid substrate are contained in the sampling tubes
Available Accessories
Optional Quantimeter 1000 automatic pump, CDS Training Sets
Expected Operational Life
Detector tubes are single-use only.
Shelf Life
<5 years; 2 years
Unit Cost
$4,000.00
Tested For Chemical Agents
GA, GB, GD, VX, DFP, DDVP, Metasystox
Tested For ITF-25 TIC/TIMs
Arsine, chlorine, HCN, phosgene
Other Chemical Targets
DA, DX, DC, DM
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm; mg/m^3
Known Interferents/Inhibitors
Not analyte specific; tubes respond to functional groups (thioethers, phosphonate esters, etc.)
Start Up Time (From Cold Start To Sample Ready)
1 minute
Response Time (Sample Application To Output)
<5 minutes
Other Operational Parameters
Detection/quantification via color change
Training Required
<1 hour training
Training Available
1 hour training
Manuals Available
User manual and color comparison charts
Reachback Service
No
Warranties
Pump: 5 years, CDS Sets: 2 years
ITAR/EAR Export Regulations
No
Please enter contact info.
Email Address: 
Company: 
Name: 