MicroFID II
The MicroFID II Flame Ionization Detector (FID) is a portable instrument designed for HAZMAT detection, confined space entry and soil gas monitoring. MicroFID II provides measurements over a wide range of VOCs, including methane. Its operating range of 0.1 ppm to 50,000 ppm helps define the severity of a hot zone. MicroFID II allows up to 70 hours of continuous use at very low pressure (80 psi) to maximize field operation up-time. Typical applications include chemical incident response, arson accelerant investigations, soil gas monitoring and petroleum products tank entry.
Availability: DISCONTINUED
| Manufacturer |
| INFICON |
| Product Name |
| MicroFID II |
| Detection Category |
| Chemical |
| Detection Principle |
| Sensors; |
| Detection Method |
| Flame Ionization Detection (FID); |
| Application |
| Emergency Response; Gas Analysis; |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The MicroFID II Flame Ionization Detector (FID) is a portable instrument designed for HAZMAT detection, confined space entry and soil gas monitoring. MicroFID II provides measurements over a wide range of VOCs, including methane. Its operating range of 0.1 ppm to 50,000 ppm helps define the severity of a hot zone. MicroFID II allows up to 70 hours of continuous use at very low pressure (80 psi) to maximize field operation up-time. Typical applications include chemical incident response, arson accelerant investigations, soil gas monitoring and petroleum products tank entry. |
| Availability |
| DISCONTINUED |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 13 x 12 x 3 in (331 x 305 x 77 mm) |
| Weight |
| <30 lbs.; 11 lbs (5 kg) |
| Power Requirements |
| NiMH Battery; 15 hour use/charge |
| Transportability |
| Person-Portable |
| Ruggedness |
| None |
| Operating Conditions |
| 0 to 50°C (32 to 122°F); 0 to 100% RH, non-condensing |
| Consumables |
| >$1,000/year; Sample Bag, ALTEF, 1L or 3L, Polymer, Septum Hydrogen fuel cylinder, Exhaust frit and housing replacement, Fluoropore filters, Calibration gas, Hydrogen fuel |
| Solvents/Reagents |
| Not Specified |
| Calibration Schedule |
| With each start up: Zero point calibration and span gas calibration must be done just prior to each day’s analysis |
| Suggested Routine Maintenance |
| ProCare annual service $486 |
| Available Accessories |
| Hydrostik Adapter Kit; Battery Charger; Gas Bag Adapter; Sample probe; Charcoal Filters; Coalescing Filters; Calibration Gas Regulator |
| Data Analysis Support Equipment |
| Handheld device (computer, PDA or mobile phone) |
| Communications Interface |
| Detection data may be displayed on an optional PDA and uploaded to a PC through its built-in Bluetooth wireless interface. |
| Expected Operational Life |
| 10+ years |
| Shelf Life |
| >5 years; Dependent on calibration gas shelf life, which varies depending on the gas used. Gases must be replaced before expiration. |
| Unit Cost |
| $11,495.00 |
| Maintenance Cost |
| $486 every year |
| Tested For Chemical Agents |
| No |
| Tested For ITF-25 TIC/TIMs |
| Yes |
| Tested For Explosives |
| No |
| Tested For Narcotics |
| No |
| Other Chemical Targets |
| Volatile organic compounds |
| Adaptability |
| Yes; user can add new targets to detector with support |
| Sample Introduction |
| Vapor/Gas |
| Sensitivity/Detection Limits |
| ppm |
| Start Up Time (From Cold Start To Sample Ready) |
| 20 minute warm up |
| Response Time (Sample Application To Output) |
| Continuous (<30 seconds); 90% of full scale in < 3 seconds |
| Alarm Capability |
| Audible and Visual |
| Software Control |
| Integrates with LeakDAS® Mobile and GuideWare monitoring software |
| Training Required |
| <1 day training |
| Training Available |
| Vendor training at customer or vendor facility |
| Manuals Available |
| Operator’s Manual |
| Warranties |
| 1 year warranty, extended warranty available |
| IATA Shipping Restrictions |
| Yes; IATA regulations apply for the fuel cylinder and calibration gases |