Innova Multigas Monitors
The Innova 1314 and 1512 are a quantitative gas monitors based on photoacoustic infrared detection. Optical filters (up to 5 + water vapor) allow the 1314 to selectively measure the concentration of up to 5 component gases and water vapor in air. Detection limits are gas-dependent but are typically in the 10-² ppm region. Photoacoustic detectors are highly sensitive, stable, and have a wide dynamic range, but are relatively non-specific and are not recommended for identification of unknowns.
Availability: Commercially Available
Andrew Hammell
+1 714 974 5560
1312 West Grove Avenue
Orange, California 92865–4134
|
|
www.gasanalyzers.com
Manufacturer |
| LumaSense Technologies, Inc. |
Product Name |
| Innova Multigas Monitors |
Detection Category |
| Chemical |
Detection Principle |
| Molecular Spectroscopy; |
Detection Method |
| Photoacoustic Detection; |
Application |
| Gas Analysis; |
Product Model Number |
| 1314, 1512 |
Equipment Type |
| Instrument |
Product Synopsis |
| The Innova 1314 and 1512 are a quantitative gas monitors based on photoacoustic infrared detection. Optical filters (up to 5 + water vapor) allow the 1314 to selectively measure the concentration of up to 5 component gases and water vapor in air. Detection limits are gas-dependent but are typically in the 10-² ppm region. Photoacoustic detectors are highly sensitive, stable, and have a wide dynamic range, but are relatively non-specific and are not recommended for identification of unknowns. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 6.9 x 15.6 x 11.8 in (175 x 396 x 300 mm) |
Weight |
| <50 lbs.; 30.8 lbs (14 kg) |
Power Requirements |
| AC/DC Line Power; Lithium Battery; 110/240 V (50 to 400 Hz), battery powered (optional) |
Transportability |
| Benchtop/Fixed |
Operating Conditions |
| 5 to 40°C (41 to 104°F) |
Consumables |
| >$1,000/year; Particulate filters |
Calibration Schedule |
| Semiannual |
Suggested Routine Maintenance |
| Particulate filters must be changed as required |
Data Analysis Support Equipment |
| Software, PC |
Communications Interface |
| RS-232, IEEE-488 (1314)
USB, ethernet, RS-232 (1512) |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Unit Cost |
| $45,400.00 |
Tested For Chemical Agents |
| GB, VX, HD |
Tested For ITF-25 TIC/TIMs |
| Yes |
Other Chemical Targets |
| VOCs (over 300 listed detection limits on vendor website) |
Adaptability |
| Yes |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| ppm; ppb |
Known Interferents/Inhibitors |
| Automatically compensates for interferences caused by environmental fluctuations |
Start Up Time (From Cold Start To Sample Ready) |
| < 30 minutes |
Response Time (Sample Application To Output) |
| <1 minute |
Alarm Capability |
| Audible |
Software Control |
| Control from front panel or PC connected via RS232 |
Other Operational Parameters |
| Optical filters are required to measure target chemical optical wavelengths and to minimize signal from interfering compounds. An internal filter wheel holds up to five filters. |
Training Required |
| <1 week training |
Training Available |
| Formal |
Manuals Available |
| User's Manual |
Warranties |
| 1 year |