Itemiser® Series
The Itemiser® DX will simultaneously detect positive and negative ions. Simultaneous detection enables the Itemiser DX to detect a broad range of explosives. It delivers simultaneous explosives and narcotics detection in a portable package. The Itemiser® 4DX and 5X has a non-radioactive-based explosives and narcotics detector. The 5X model has modified sampling wand, software algorithms, a faster clear down, and the ability to remote monitor.
Availability: Commercially Available
Manufacturer |
| Rapiscan Systems |
Product Name |
| Itemiser® Series |
Detection Category |
| Chemical; Explosives |
Detection Principle |
| Spectrometry; |
Detection Method |
| Ion Trap Mobility Spectrometry; |
Application |
| Emergency Response; Gas Analysis; Screening; Trace Analysis; Bulk Analysis; |
Product Model Number |
| DX, 4DX, 5X |
Equipment Type |
| Instrument |
Product Synopsis |
| The Itemiser® DX will simultaneously detect positive and negative ions. Simultaneous detection enables the Itemiser DX to detect a broad range of explosives. It delivers simultaneous explosives and narcotics detection in a portable package. The Itemiser® 4DX and 5X has a non-radioactive-based explosives and narcotics detector. The 5X model has modified sampling wand, software algorithms, a faster clear down, and the ability to remote monitor. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Supporting Documentation |
| Docs: Rapiscan systems-itemiser-4dx.pdf; Rapiscan - Itemiser DX.pdf; MRIGlobal - Itemiser DX Series.pdf; |
Dimensions |
| 19.8 x 18.9 x 14.9 in (5 x 4.8 x 3.8 cm) Display Clearance 16.3 in (41cm) |
Weight |
| <30 Lbs.; 26.5 Lbs. (12 kg) |
Power Requirements |
| AC/DC Line Power; Standard AC Input: 100 to 120 VAC, 200 to 240 VAC, 47 to 63 Hz, 150 W -DC Input: 11 to 18 VDC input, 10 A (150 W) max |
Transportability |
| Benchtop/Fixed; Small Footprint |
Ruggedness |
| Vibration/Shock; ISTA Procedure 2 which is drop and vibration |
Operating Conditions |
| 0 to 40°C (32 to 104°F) ; 0 to 95%RH, non-condensing |
Consumables |
| >$1,000/year; Calibration traps, sample traps, dopants, mesh screens |
Calibration Schedule |
| Once per shift or every 8 to10 hours |
Suggested Routine Maintenance |
| 10 minutes per week |
Available Accessories |
| Vacuum wand |
Data Analysis Support Equipment |
| PC |
Communications Interface |
| Two USB 2.0 ports, Ethernet port |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Unit Cost |
| $40,000.00 |
Maintenance Cost |
| $2,000 to $2,500 per year |
Tested For Chemical Agents |
| Amenable based on technology |
Tested For ITF-25 TIC/TIMs |
| Amenable based on technology |
Tested For Explosives |
| Yes |
Tested For Narcotics |
| Yes |
Other Chemical Targets |
| Amenable based on technology |
Adaptability |
| No; cannot detect or add new targets |
Sample Introduction |
| Solid; Liquid |
Sensitivity/Detection Limits |
| ng |
Start Up Time (From Cold Start To Sample Ready) |
| 30 minutes |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds); 8 seconds |
Total Run Time |
| 30 minutes |
Alarm Capability |
| Audible and visual |
Software Control |
| On-board; PC; Remote |
Training Required |
| <1 week training |
Training Available |
| Yes; in-person and online |
Manuals Available |
| Yes |
Reachback Service |
| Yes; 24/7 while under warranty |
Warranties |
| 1 year parts and labor. Extended warranties available. |
IATA Shipping Restrictions |
| Yes; IATA regulations may apply |