CW Sentry 3G

The CW Sentry 3G uses a surface acoustic wave (SAW) sensor array with a thermally modulated sample collector to detect CWAs and avoid false positives. To expand the CW Sentry’s capabilities, an electrochemical sensor array is added to detect TICs. Analysis data can be reported via RS232, Ethernet, fiber optic, or switch closures.

Notify me on updates of this product 

Availability: Commercially Available

Steven Schmidt
Sales Development Manager, Government
steve.schmidt@msanet.com
+1 800 672 2222
1000 Cranberry Woods Drive
Cranberry Township, PA 16066
USA
www.msasafety.com
Manufacturer
Mine Safety Appliances Company (MSA)
Product Name
CW Sentry 3G
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Electrochemical Detection;Surface Acoustic Wave Detection;
Application
Emergency Response; Gas Analysis;
Equipment Type
Instrument
Product Synopsis
The CW Sentry 3G uses a surface acoustic wave (SAW) sensor array with a thermally modulated sample collector to detect CWAs and avoid false positives. To expand the CW Sentry’s capabilities, an electrochemical sensor array is added to detect TICs. Analysis data can be reported via RS232, Ethernet, fiber optic, or switch closures.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
24.75 × 19.5 × 9.5 in (630 x 500 x 240 mm)
Weight
<50 lbs.; 40 lbs (18 kg)
Power Requirements
AC/DC Line Power; 90 to 240 V, 50/60 Hz (60 W)
Transportability
Benchtop/Fixed
Ruggedness
Extreme Temperatures/Humidity; Designed to operate in a controlled environment.
Operating Conditions
-20 to 50°C (-4 to 122°F), 10 to 95% RH
Consumables
<$1,000/year; Particulate filters. Designed to be low maintenance.
Calibration Schedule
SAW sensors require no calibration. Electrochemical cells require recalibration every 6 months (sold as an option).
Suggested Routine Maintenance
Replace electrochemical sensor every 1 year
Communications Interface
RS232, Ethernet and fiber optic ports (optional). Designed to integrate with common surety and fire systems.
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$28,968.00
Maintenance Cost
Est. $350 to $500 per year
Tested For Chemical Agents
GA, GB, GD, GF, VX, HD, HN3
Tested For ITF-25 TIC/TIMs
Hydrogen cyanide, phosgene, arsine, chlorine, diborane, fluorine, sulfur dioxide, ethylene oxide, cyanogen chloride
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm
Known Interferents/Inhibitors
SAW sensor have greater than 95% resistance to interferents. Electrochemical cells are less selective, depending on the selected cell.
Start Up Time (From Cold Start To Sample Ready)
< 5 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds); 30 seconds for SAW sensor; 5 seconds for electrochemical cell array
Total Run Time
Seconds
Alarm Capability
Audible and visual
Software Control
Yes
Other Operational Parameters
Simultaneous detection of nerve, blister, blood, and choke agents and class identification of TICs
Training Required
<1 week training
Training Available
30 minutes training
Manuals Available
Operator’s manual
Warranties
1 year parts and labor
Please enter contact info.
Email Address: 
Company: 
Name: 