SMART-II Biological Warfare Detection Tickets

The SMART-II tickets are available for a panel of analytes. Once the sample is acquired, it is suspended in a buffer and administered onto the strip. The liquid sample is wicked across a pad that will develop over the course of 15 to 30 minutes with a control line to validate the test as well as a detection line which indicates presence/absence of analyte.

Notify me on updates of this product 

Availability: Commercially Available

Arlette Loomis
arlettel@nhdiag.com
+1 443 543 5746
1450 South Rolling Road
Baltimore, Maryland 21227
USA
www.nhdiag.com
Manufacturer
New Horizons Diagnostic Corporation
Product Name
SMART-II Biological Warfare Detection Tickets
Detection Category
Biological
Detection Principle
Immunological;
Detection Method
Lateral Flow Hand Held Immunoassay ;
Application
Laboratory Analysis; Detection;
Equipment Type
Instrument
Product Synopsis
The SMART-II tickets are available for a panel of analytes. Once the sample is acquired, it is suspended in a buffer and administered onto the strip. The liquid sample is wicked across a pad that will develop over the course of 15 to 30 minutes with a control line to validate the test as well as a detection line which indicates presence/absence of analyte.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Supporting Documentation
Docs: New Horizons - SmartII.pdf;
Dimensions
0.5 x .24 x 2 in (1.3 x 0.6 x 5.1 cm)
Weight
<1 lb.; < 1 oz (27.3 g)
Power Requirements
None
Noise Produced
None
Transportability
Pocket Size
Operating Conditions
10 to 40°C (50 to 105°F)
Consumables
<$1,000/year; Buffer solution
Solvents/Reagents
Chase buffer
Calibration Schedule
None
Suggested Routine Maintenance
None
Available Accessories
Sample collection kits
Data Analysis Support Equipment
Sample acquisition/collection system sold in a selection of several kits available through New Horizons website.
Expected Operational Life
Single use item
Shelf Life
<1 year
Unit Cost
$550 per 25 pack
Maintenance Cost
$22 per sample
Tested For Biological Agents
B. anthracis (Anthrax), Y. pestis (Plague) Cholera toxin, Ricin, Staph Enterotoxin B (SEB), F. tularensis (Tularemia), Botulinum toxin
Other Biological Targets
Yes
Adaptability
Yes
Sample Introduction
Liquid
Sensitivity/Detection Limits
Genome Equivalent/mL; 10^5 of each of target organisms/mL; anthrax 100,000 spores/mL.Unspecified for toxins
Start Up Time (From Cold Start To Sample Ready)
None
Response Time (Sample Application To Output)
>15 minutes; 15 minutes to 30 minutes, depending on development of a positive result.
Total Run Time
30 minutes
Alarm Capability
No
Training Required
<1 day training
Training Available
No
Manuals Available
Yes
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: