Model 312

Model 312 is a portable gas chromatograph that can be configured with a variety of detectors, including photoionization (PID), flame ionization (FID), thermal conductivity (TCD), flame photometric (FPD), far UV absorbance (FUV), or catalytic combustion (CCD).

Notify me on updates of this product 

Availability: Commercially available

Jack Driscoll
sales@hnu.com
+1 774 413 5281
780 Corporate Park Drive
Pembroke, MA 02359
USA
www.hnu.com
Manufacturer
PID Analyzers LLC
Product Name
Model 312
Detection Category
Chemical; Explosives
Detection Principle
Chromatography;Sensors;
Detection Method
Flame Ionization Detection (FID);Flame Photometric Detection (FPD);Photo Ionization Detection;
Application
Emergency Response; Gas Analysis;
Equipment Type
Instrument
Product Synopsis
Model 312 is a portable gas chromatograph that can be configured with a variety of detectors, including photoionization (PID), flame ionization (FID), thermal conductivity (TCD), flame photometric (FPD), far UV absorbance (FUV), or catalytic combustion (CCD).
Availability
Commercially available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
18.75 × 13.75 × 7.5 in (188 x 138 x 75 mm)
Weight
<30 lbs.; 27.5 lbs (12.5 kg)
Power Requirements
AC/DC Line Power; NiMH Battery; 50 W maximum power; 115 V AC, 0.5 A (12 V DC, 5 A) Battery (3 to 4 hours lifetime); Optional cigarette lighter adapter
Transportability
Person-Portable
Ruggedness
None; Glass fiber casing, drop sensitive
Operating Conditions
5 to 40°C (41 to 104°F)
Consumables
<$1,000/year; Carrier gas
Solvents/Reagents
Carrier gas
Calibration Schedule
Manual calibration
Data Analysis Support Equipment
Software
Communications Interface
USB
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$19,500.00
Maintenance Cost
GC columns, carrier gas
Tested For Chemical Agents
Yes
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
Yes
Tested For Narcotics
Yes
Other Chemical Targets
Volatile organic chemicals
Adaptability
Yes, user can add new targets to detector with support using PC software
Sample Introduction
Vapor/Gas; Liquid
Sensitivity/Detection Limits
ppb; ppm
Start Up Time (From Cold Start To Sample Ready)
< 30 minutes
Response Time (Sample Application To Output)
<15 minutes
Total Run Time
Minutes
Software Control
Peakworks program
Other Operational Parameters
Linear dynamic range of detectors: PID: 108 FID: 2 × 106 TCD: 2 × 104 FPD: Sulfur, 103; Phosphorus, 105 Far UV: 106 CCD: 5 × 104
Training Required
<1 week training
Training Available
Yes
Manuals Available
Yes
ITAR/EAR Export Regulations
Yes; Carrier gas cylinder must be shipped per IATA restrictions for compressed gas.
IATA Shipping Restrictions
Yes; Carrier gas cylinder must be shipped per IATA restrictions for compressed gas.
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: