AP4C-F

The AP4C-F is a 24/7 rugged, real-time universal chemical threat detector for naval and critical infrastructure protection. AP4C-F is a stationary monitor that can measure and detect chemical threats in real-time in either vapor, gas and aerosol form. Whether you need to protect vessels or building ventilation systems for critical infrastructure, the AP4C-F protects your assets thanks to its extremely short response time and unrivaled detection performancesThe device is designed to run continuously and has the durability to withstand harsh environments.

Notify me on updates of this product 

Availability: Commercially Available

Scott Hartley
CEO
scott.hartley@proengin.com
+1 954 760 9990
1322 Central Park Boulevard, Suite 408
Fredericksburg, VA 22403
USA
www.proengin.com
Manufacturer
Proengin, Inc.
Product Name
AP4C-F
Detection Category
Chemical;
Detection Principle
Elemental Analysis;
Detection Method
Flame Spectroscopy;
Application
Emergency Response; Gas Analysis;
Equipment Type
Instrument
Product Synopsis
The AP4C-F is a 24/7 rugged, real-time universal chemical threat detector for naval and critical infrastructure protection. AP4C-F is a stationary monitor that can measure and detect chemical threats in real-time in either vapor, gas and aerosol form. Whether you need to protect vessels or building ventilation systems for critical infrastructure, the AP4C-F protects your assets thanks to its extremely short response time and unrivaled detection performancesThe device is designed to run continuously and has the durability to withstand harsh environments.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Supporting Documentation
Docs: DTAP4CF04EN_PNG-2022-0193-A.pdf;
Dimensions
13.1 x 15.7 x 23,9 in (332 x 400 x 606 mm)
Weight
<50 lbs.; 31 lbs (15 kg)
Power Requirements
AC/DC Line Power; AC power: 24 VDC x 3 A max
Noise Produced
Low humming sound
Transportability
Mounted
Ruggedness
Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; Vibration/Shock; EMC requirements
Operating Conditions
-25 to 55°C (-13 to 131°F) 93% HR (non-condensing)
Consumables
<$1000/year; Demineralized water, filter
Solvents/Reagents
None
Calibration Schedule
Self-test on startup requires no user input
Suggested Routine Maintenance
1 L of demineralized water added monthly Recommended preventive maintenance of 2 year
Available Accessories
Control Box
Data Analysis Support Equipment
Computer
Communications Interface
RS 485; Jupiter® connector
Expected Operational Life
10 years
Shelf Life
>5 years
Maintenance Cost
Monthly: distilled water Every 6 months: Coalescent filter Annual maintenance: Every 3 years: PM/parts and calibration
Tested For Chemical Agents
Yes
Tested For ITF-25 TIC/TIMs
Yes
Other Chemical Targets
Any chemical that contains target elements will produce a response (P, HNO bond, As and/or S).
Adaptability
Not applicable; Elemental analysis performs on any threats containing P, S, As, HNO, within LOD limits; Elemental analysis do not use librairy
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
µg; ppb
Known Interferents/Inhibitors
Any chemical that contains target elements will produce a response (P, HNO bond, As and/or S).
Start Up Time (From Cold Start To Sample Ready)
1.5 hours to come to ready and is designed to stay on indefinitely
Response Time (Sample Application To Output)
Continuous (vapor, gas, aerosols) (<30 seconds); Custom times of integration from 1 seconds to 128 minutes
Alarm Capability
Audible and Visual (External)
Software Control
Yes, available separately. But it still needs to be turned on manually
Other Operational Parameters
Yes
Training Required
<1 day training
Training Available
Vendor training at customer’s facility
Manuals Available
Operator’s Manual
Warranties
1 year; extended warranties are available
ITAR/EAR Export Regulations
No
IATA Shipping Restrictions
No
Please enter contact info.
Email Address: 