EVM Series
The EVM is designed for comprehensive indoor air quality analysis with its ability to simultaneously monitor and log one toxic gas, carbon dioxide, relative humidity and temperature. Multi-sensor instrument designed for indoor air quality investigations. Simultaneously tracks, logs and monitors multiple indoor air quality parameters, including room air exchange rates and dew point. The EVM7 also monitors particulate and aerosol in the air. VOC vapors are also detected by the EVM7.
Availability: Commercially Available
+1 262 567 9157
1060 Corporate Center Drive
Oconomowoc, WI 53066
USA
|
|
www.3M.com
Manufacturer |
| TSI, Inc. |
Product Name |
| EVM Series |
Detection Category |
| Chemical; |
Detection Principle |
| Molecular Spectroscopy; Sensors; |
Detection Method |
| Photoionization Detection; Electrochemical Detection; |
Application |
| Gas Analysis; |
Product Model Number |
| EVM4, EVM7 |
Equipment Type |
| Instrument |
Product Synopsis |
| The EVM is designed for comprehensive indoor air quality analysis with its ability to simultaneously monitor and log one toxic gas, carbon dioxide, relative humidity and temperature. Multi-sensor instrument designed for indoor air quality investigations. Simultaneously tracks, logs and monitors multiple indoor air quality parameters, including room air exchange rates and dew point. The EVM7 also monitors particulate and aerosol in the air. VOC vapors are also detected by the EVM7. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Supporting Documentation |
| Docs: QUEST-EVM-Environmental-Monitors_A4_5002160_RevE.pdf; |
Dimensions |
| 7.5 x 7.5 x 2.75 in (19 x 19 x 7 cm) |
Weight |
| <5 lbs.; 2.9 lbs (1.3 kg) |
Power Requirements |
| Lithium Battery; AC/DC Line Power; Rechargeable Li-ion (minimum of 8 hours under continuous operation) 10 – 16 V power inlet , 1.5 A Universal AC Adapter 100 – 240 VAC, 50/60 Hz |
Transportability |
| Handheld |
Ruggedness |
| None; Not militarized, drop sensitive |
Operating Conditions |
| 0 to 50°C (32 to 122°F); 0 to 95% RH, non-condensing |
Consumables |
| <$1,000/year; gas sensors (interchangeable) |
Calibration Schedule |
| Annual factory calibration (AZ road dust), calibrate prior to long log events, pump calibrated annually |
Suggested Routine Maintenance |
| Filter replacement, PID cleaning, impactor cleaning |
Available Accessories |
| Calibration gases, HEPA filter, Air Probe |
Communications Interface |
| USB |
Expected Operational Life |
| 10 years |
Shelf Life |
| >5 years; (battery must be charged every 6 months) |
Unit Cost |
| $8,000.00 |
Tested For ITF-25 TIC/TIMs |
| Yes |
Other Chemical Targets |
| Combustibles gases, particulates |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| ppm |
Known Interferents/Inhibitors |
| Acidic vapors reduce sensitivity |
Start Up Time (From Cold Start To Sample Ready) |
| < 5 minutes |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
Total Run Time |
| Continuous |
Alarm Capability |
| Visual |
Software Control |
| On-board, QuestSuite Professional II |
Other Operational Parameters |
| 1.67 L/min flow rate |
Training Required |
| <1 day training |
Manuals Available |
| User Manuals and quick start guides |
Warranties |
| 1 year |
IATA Shipping Restrictions |
| Yes; Calibration gas cylinder must be shipped per IATA restrictions for compressed gas. |