Fidamat 6 Continuous Gas Analyzer
The FIDAMAT versions cover trace measurement of hydrocarbons in pure gases (made possible by high resolution and low differences in the response factors), to total content measurement for hydrocarbons in the presence of corrosive gases. The high, adjustable operating temperature for the internal gas path and the detector also allows the measurement of high-boiling mixtures and the measurement of hydrocarbons at vapor concentrations of up to 100%. There is no need for an external computer.
Availability: Commercially Available
Manufacturer |
| Siemens Industry, Inc. |
Product Name |
| Fidamat 6 Continuous Gas Analyzer |
Detection Category |
| Chemical |
Detection Principle |
| Sensors; |
Detection Method |
| Flame Ionization Detection (FID) ; |
Application |
| Emergency Response; Gas Analysis; |
Equipment Type |
| Sensor |
Product Synopsis |
| The FIDAMAT versions cover trace measurement of hydrocarbons in pure gases (made possible by high resolution and low differences in the response factors), to total content measurement for hydrocarbons in the presence of corrosive gases. The high, adjustable operating temperature for the internal gas path and the detector also allows the measurement of high-boiling mixtures and the measurement of hydrocarbons at vapor concentrations of up to 100%. There is no need for an external computer. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 19 x 17.3 x 6.97 in (483 x 440 x 177 mm) |
Weight |
| >50 lbs.; 50.7 lbs (23 kg) |
Power Requirements |
| AC/DC Line Power; Power Requirements 100 to 120 V AC and 200 to 240 V AC |
Transportability |
| Benchtop/Fixed |
Ruggedness |
| None; drop sensitive |
Operating Conditions |
| 0 to 200°C (measuring gas entry temperature) 5 to 45°C (ambient operating temperature) -30 to 70°C (ambient storage temperature) <90% Relative Humidity (gas entry humidity) <90% Relative Humidity (ambient, cannot fall below dew point) 18 – 60 l/hr (measuring gas flow rate) Keep the unit out of direct sunlight |
Consumables |
| <$1,000/year; Gases for operation: combustion gas, sample gas, zero gas and calibration gas. |
Calibration Schedule |
| Yes |
Communications Interface |
| RS 485/RS 232 converter, RS 485/Ethernet converter, and RS 485/USB converter are available, Additionally purchased capabilities: AUTOCAL function (each with 8 binary inputs/outputs) |
Other Chemical Targets |
| Measures Total Hydrocarbons |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| ppm; ppb |
Known Interferents/Inhibitors |
| O2 in N2 (21 vol.%) < 0.3 mg/m3, SO2 in N2 (258 mg/m3) < 0.15 mg/m3 NO in N2 (310 mg/m3) < 0.5 mg/m3 NO2 in synth. air (146 mg/m3) < 0.1 mg/m3 CO in N2 (461 mg/m3) < 0.15 mg/m3 CO2 in N2 (18 vol.%) < 0.1 mg/m3 HCl in N2 (78 mg/m3) < 0.3 mg/m3 |
Start Up Time (From Cold Start To Sample Ready) |
| 2-3 hours at room temperature |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds); T90 - 2 to 3 seconds Time for device-internal signal processing < 1 s |
Alarm Capability |
| Yes |
Software Control |
| Incorporation in networks via PROFIBUS; SIPROM GA software as service and maintenance tool |
Training Required |
| <1 week training |
Training Available |
| Yes |
Manuals Available |
| Operator’s Manual |
Warranties |
| 18 month |
IATA Shipping Restrictions |
| Yes; gases are regulated by IATA |