Fidamat 6 Continuous Gas Analyzer

The FIDAMAT versions cover trace measurement of hydrocarbons in pure gases (made possible by high resolution and low differences in the response factors), to total content measurement for hydrocarbons in the presence of corrosive gases. The high, adjustable operating temperature for the internal gas path and the detector also allows the measurement of high-boiling mixtures and the measurement of hydrocarbons at vapor concentrations of up to 100%. There is no need for an external computer.

Notify me on updates of this product 

Availability: Commercially Available

Gregg Meidl
sales
gregg.meidl@siemens.com
918-662-7409
408 US Hwy 60
Bartlesville, OK 74003
Manufacturer
Siemens Industry, Inc.
Product Name
Fidamat 6 Continuous Gas Analyzer
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Flame Ionization Detection (FID) ;
Application
Emergency Response; Gas Analysis;
Equipment Type
Sensor
Product Synopsis
The FIDAMAT versions cover trace measurement of hydrocarbons in pure gases (made possible by high resolution and low differences in the response factors), to total content measurement for hydrocarbons in the presence of corrosive gases. The high, adjustable operating temperature for the internal gas path and the detector also allows the measurement of high-boiling mixtures and the measurement of hydrocarbons at vapor concentrations of up to 100%. There is no need for an external computer.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
19 x 17.3 x 6.97 in (483 x 440 x 177 mm)
Weight
>50 lbs.; 50.7 lbs (23 kg)
Power Requirements
AC/DC Line Power; Power Requirements 100 to 120 V AC and 200 to 240 V AC
Transportability
Benchtop/Fixed
Ruggedness
None; drop sensitive
Operating Conditions
0 to 200°C (measuring gas entry temperature) 5 to 45°C (ambient operating temperature) -30 to 70°C (ambient storage temperature) <90% Relative Humidity (gas entry humidity) <90% Relative Humidity (ambient, cannot fall below dew point) 18 – 60 l/hr (measuring gas flow rate) Keep the unit out of direct sunlight
Consumables
<$1,000/year; Gases for operation: combustion gas, sample gas, zero gas and calibration gas.
Calibration Schedule
Yes
Communications Interface
RS 485/RS 232 converter, RS 485/Ethernet converter, and RS 485/USB converter are available, Additionally purchased capabilities: AUTOCAL function (each with 8 binary inputs/outputs)
Other Chemical Targets
Measures Total Hydrocarbons
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm; ppb
Known Interferents/Inhibitors
O2 in N2 (21 vol.%) < 0.3 mg/m3, SO2 in N2 (258 mg/m3) < 0.15 mg/m3 NO in N2 (310 mg/m3) < 0.5 mg/m3 NO2 in synth. air (146 mg/m3) < 0.1 mg/m3 CO in N2 (461 mg/m3) < 0.15 mg/m3 CO2 in N2 (18 vol.%) < 0.1 mg/m3 HCl in N2 (78 mg/m3) < 0.3 mg/m3
Start Up Time (From Cold Start To Sample Ready)
2-3 hours at room temperature
Response Time (Sample Application To Output)
Continuous (<30 seconds); T90 - 2 to 3 seconds Time for device-internal signal processing < 1 s
Alarm Capability
Yes
Software Control
Incorporation in networks via PROFIBUS; SIPROM GA software as service and maintenance tool
Training Required
<1 week training
Training Available
Yes
Manuals Available
Operator’s Manual
Warranties
18 month
IATA Shipping Restrictions
Yes; gases are regulated by IATA