Siprocess UV600 Continuous Gas Analyzer
SIPROCESS UV600 is an extractive UV gas analyzer that can simultaneously measure up to three components. The measuring principle is based on the molecule-specific absorption of gases in the ultraviolet wavelength range. Radiation of a wavelength appropriate to the measurement is passed through the sample, and the selective absorption which is proportional to the concentration of the measured component is determined.
Availability: Commercially Available
| Manufacturer |
| Siemens Industry, Inc. |
| Product Name |
| Siprocess UV600 Continuous Gas Analyzer |
| Detection Category |
| Chemical |
| Detection Principle |
| Molecular Spectroscopy; |
| Detection Method |
| Ultraviolet-Visible; |
| Application |
| Emergency Response; Gas Analysis; |
| Equipment Type |
| Sensor |
| Product Synopsis |
| SIPROCESS UV600 is an extractive UV gas analyzer that can simultaneously measure up to three components. The measuring principle is based on the molecule-specific absorption of gases in the ultraviolet wavelength range. Radiation of a wavelength appropriate to the measurement is passed through the sample, and the selective absorption which is proportional to the concentration of the measured component is determined. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 19 x 15.9 x 6.97 in (483 x 405 x 178 mm) |
| Weight |
| <50 lbs.; 37.5 lbs (17 kg) |
| Power Requirements |
| AC/DC Line Power; 100 to 120 V AC, 200 to 220 V AC |
| Transportability |
| Benchtop/Fixed |
| Ruggedness |
| None; drop sensitive |
| Operating Conditions |
| Operation: +5 to 45°C (41 to 113° F) Transport and storage: -10 to 70°C (14 to 158° F) Relative humidity: 10 to 95%, non-condensing |
| Consumables |
| >$1,000/year; Calibration gas, zero span gas, safety filter, power supply units, 24 V DC, distribution board, FKM hose d = 3/5, length = 1 m, MEDL UV lamp with heater 1, motor flange, motor flange, gas filter with holder, for measurement of NO, SIPROCESS UV600 chamber H = 300 mm, aluminum, calibration chamber with holder for NO, calibration chamber with holder for SO2 and H2S, calibration chamber with holder for NO2, heater with 380 mm long cable, for SIPROCESS UV600: MEDL, chamber, motor flange, moisture sensor, spare parts set - pressure sensor with gasket and O-ring, flow sensor with temperature sensor, diaphragm pump type 123, 24 V DC / 50 Hz, diaphragm assembly, EPDM for types 110-125, and an o-ring for gas pump suspension |
| Calibration Schedule |
| Yes |
| Suggested Routine Maintenance |
| Minimal, little or no maintenance other than UV lamp |
| Data Analysis Support Equipment |
| Second IO module, optional calibration unit, flow monitor, humidity monitor, pressure sensor |
| Communications Interface |
| Ethernet, Si-Process-UV-600-specific software tool |
| Shelf Life |
| <5 years; 2 years |
| Unit Cost |
| $28,000.00 |
| Maintenance Cost |
| Minimal |
| Other Chemical Targets |
| Measures: NO, NO2, SO2 or H2S |
| Sample Introduction |
| Vapor/Gas |
| Sensitivity/Detection Limits |
| ppm |
| Known Interferents/Inhibitors |
| The sample gases must be fed into the analyzers free of dust. Condensation in the sample chambers must be prevented. Therefore, the use of gas modified for the measuring task is necessary in most application cases. |
| Start Up Time (From Cold Start To Sample Ready) |
| 1 hr |
| Response Time (Sample Application To Output) |
| Continuous (<30 seconds); T90 – up to 10 seconds |
| Alarm Capability |
| Yes |
| Software Control |
| May be parameterized and operated using a PDM tool. The analyzers can optionally communicate with the Siprom GA software tool that is integrated into the Ethernet via TCP/IP. |
| Training Required |
| <1 week training |
| Training Available |
| Yes |
| Manuals Available |
| Operator’s Manual |
| Warranties |
| 18 month |
| IATA Shipping Restrictions |
| Yes; gases are regulated by IATA |