iSpin-NMR
The iSpin-NMR can serve as a complete console for NMR or NQR with spectrometer frequencies from 0 to 100 MHz. NMR experiments can be performed once connected to a probe placed in a magnetic field. SpinCore Technologies, Inc. also markets permanent magnets, probes, and BNC connections specific to the frequency of interest. The iSpin-NMR console is simply the radio-frequency generation and amplification electronics.
Availability: Commercially Available
| Manufacturer |
| SpinCore Technologies, Inc. |
| Product Name |
| iSpin-NMR |
| Detection Category |
| Chemical |
| Detection Principle |
| Molecular Spectroscopy; |
| Detection Method |
| Nuclear Magnetic Resonance ; |
| Application |
| Laboratory Analysis; |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The iSpin-NMR can serve as a complete console for NMR or NQR with spectrometer frequencies from 0 to 100 MHz. NMR experiments can be performed once connected to a probe placed in a magnetic field. SpinCore Technologies, Inc. also markets permanent magnets, probes, and BNC connections specific to the frequency of interest. The iSpin-NMR console is simply the radio-frequency generation and amplification electronics. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| Market Entry Date |
| 2007 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Supporting Documentation |
| Docs: SpinCore - iSpin-NMR.pdf; MRIGlobal - iSpinNMR.pdf; |
| Dimensions |
| 19 x 11 x 4 in (48 x 28 x 10 cm) |
| Weight |
| <30 lbs.; 10 lbs (4.5 kg) |
| Power Requirements |
| AC/DC Line Power; Universal AC input power supply (90 to 240 VAC) |
| Transportability |
| Benchtop/Fixed; Small Footprint |
| Ruggedness |
| None; Due to the tuned components of the internal sample probe dropping equipment is not recommended. |
| Operating Conditions |
| 15 to 28°C (59 to 82°F); 35 to 70%RH non-condensing |
| Consumables |
| <$1,000/year; Glass NMR tubes, deuterated solvents |
| Solvents/Reagents |
| Deuterated solvents |
| Calibration Schedule |
| Application dependent |
| Suggested Routine Maintenance |
| User may need to shim the magnet |
| Available Accessories |
| Requires probe, magnet, and associated cables for excitation and detection wavelengths |
| Data Analysis Support Equipment |
| Microsoft Windows 7, Vista, XP |
| Communications Interface |
| USB |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| >5 years |
| Unit Cost |
| $12,995.00 |
| Tested For Chemical Agents |
| Chemical agents that have protons (1H) can be detected |
| Tested For ITF-25 TIC/TIMs |
| TIC/TIM that have protons (1H) can be detected |
| Tested For Explosives |
| Explosives (nitroaromatics, organic peroxides) that have protons (1H) can be detected |
| Tested For Narcotics |
| Narcotics that have protons (1H) can be detected |
| Other Chemical Targets |
| Chemicals that have protons (1H) can be detected |
| Adaptability |
| No; cannot detect or add new targets |
| Sample Introduction |
| Liquid |
| Sensitivity/Detection Limits |
| ppm; ppth |
| Known Interferents/Inhibitors |
| Mixtures containing molecules each with protons will lead to spectra that will need some expert interpretation |
| Start Up Time (From Cold Start To Sample Ready) |
| < 1 hour |
| Response Time (Sample Application To Output) |
| >15 minutes; 1 min to hours |
| Total Run Time |
| 1 hour |
| Software Control |
| PC |
| Other Operational Parameters |
| Comes with any customer specified frequency from 1 - 100 MHz. Can also be configured to analyze for other NMR-active nuclei (e.g. 29Si, 31P, 13C). |
| Training Required |
| <1 day training |
| Training Available |
| Not available, the systems are designed to be customizable for expert spectroscopists |
| Manuals Available |
| Yes |
| Reachback Service |
| Yes, free 20 hours telephone/email support in the first 3 months after purchase date. |
| Warranties |
| One year from the invoice date, 30-day money back guarantee |
| Data File Type Format |
| ASCII, JCAMP-DX, and Felix (binary) |