microPHAZIR
The microPHAZIR ™ RX analyzer provides pharmaceutical manufacturers with a portable tool to analyze products directly on the manufacturing line in order to meet regulatory requirements, improve product quality, and reduce manufacturing costs.
Availability: Commercially Available
Manufacturer |
| Thermo Fisher Scientific, Inc. |
Product Name |
| microPHAZIR |
Detection Category |
| Chemical; Explosives |
Detection Principle |
| Molecular Spectroscopy; |
Detection Method |
| Near Infrared; |
Application |
| Bulk Analysis; Laboratory Analysis; |
Product Model Number |
| MICROPHAZIRRX |
Equipment Type |
| Instrument |
Product Synopsis |
| The microPHAZIR ™ RX analyzer provides pharmaceutical manufacturers with a portable tool to analyze products directly on the manufacturing line in order to meet regulatory requirements, improve product quality, and reduce manufacturing costs. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Supporting Documentation |
| Docs: Thermo Scientific-MicroPHAZIR RX.pdf; |
Dimensions |
| 9.6 x 9.1 x 3.8 in (24.4 x 23.2 x 9.7 cm) |
Weight |
| <5 Lbs.; 2.75 Lbs. (1.25 kg) |
Power Requirements |
| Lithium Battery; AC/DC Line Power; Interchangeable, rechargeable 5+ hours lithium ion battery pack AC battery charger |
Transportability |
| Handheld |
Ruggedness |
| None; Not militarized, drop sensitive |
Consumables |
| None |
Calibration Schedule |
| Factory tested, includes certificate of compliance |
Available Accessories |
| Holster with battery compartment, Spare battery, Polychromix Method Generation software, Validation support services |
Data Analysis Support Equipment |
| PC, software |
Communications Interface |
| USB |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Unit Cost |
| $41,000.00 |
Tested For Chemical Agents |
| Amenable based on technology |
Tested For ITF-25 TIC/TIMs |
| Amenable based on technology |
Tested For Explosives |
| Amenable based on technology |
Tested For Narcotics |
| Amenable based on technology |
Other Chemical Targets |
| Pharmaceutical impurities, excipients, APIs |
Number of Library Entries |
| Not Specified |
Adaptability |
| Yes; user can add new targets in the field |
Sample Introduction |
| Solid; Liquid |
Sensitivity/Detection Limits |
| Bulk; mg; g; % |
Known Interferents/Inhibitors |
| Successful identification of an unknown is dependent on the presence of the corresponding reference spectrum in the library. |
Start Up Time (From Cold Start To Sample Ready) |
| 10 minutes |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds); 3 seconds |
Total Run Time |
| 1 minute |
Alarm Capability |
| Visual |
Software Control |
| On-board software |
Training Required |
| <1 day training |
Training Available |
| Yes |
Manuals Available |
| Yes |
Warranties |
| 1 year |
IATA Shipping Restrictions |
| Yes, Lithium ion battery |