TVA 1000B Toxic Vapor Analyzer

The Thermo Scientific TVA 1000B is an over-the-shoulder portable vapor analyzer that offers both PID (Photoionization Detection) and FID (Flame Ionization Detection) in a single, instrument. The user can monitor and log inorganic and organic vapors simultaneously.

Notify me on updates of this product 

Availability: DISCONTINUED

+1 978 642 1132
46 Jonspin Road
Wilmington, MA 01887
USA
www.thermoscientific.com
Manufacturer
Thermo Fisher Scientific, Inc.
Product Name
TVA 1000B Toxic Vapor Analyzer
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Photoionization Detection; Flame Ionization Detection (FID) ;
Application
Emergency Response; Gas Analysis;
Product Model Number
Multiple
Equipment Type
Instrument
Product Synopsis
The Thermo Scientific TVA 1000B is an over-the-shoulder portable vapor analyzer that offers both PID (Photoionization Detection) and FID (Flame Ionization Detection) in a single, instrument. The user can monitor and log inorganic and organic vapors simultaneously.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
13.5 × 10.3 × 3.2 in (343 × 262 × 81 mm)
Weight
<30 Lbs.; 13 Lbs. (5.8 kg)
Power Requirements
NiMH Battery; Rechargeable NiCd Battery
Transportability
Person-Portable
Operating Conditions
0 to 40°C (32 to 104°F)
Consumables
<$1,000/year; Hydrogen gas, and calibration gas
Calibration Schedule
Yes, a calibration kit with a gas cylinder can be purchased with the instrument for daily calibration.
Available Accessories
Carrying case, charcoal filter, FID calibration kit, PID/FID calibration kit, and Bluetooth communication module
Communications Interface
Data logger software is included
Expected Operational Life
8 hours
Shelf Life
<5 years; If purchased, a PID could need replacement after a year or two, depending on exposure to contaminates
Unit Cost
$9,829.00
Maintenance Cost
Gas and battery replacement as needed. Est: <$200 per year
Tested For Chemical Agents
Some
Tested For ITF-25 TIC/TIMs
Yes, VOCs
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppb
Known Interferents/Inhibitors
Alarms to hydrocarbon fumes
Start Up Time (From Cold Start To Sample Ready)
15 to 20 minutes depending upon surrounding temperatures
Response Time (Sample Application To Output)
Continuous (<30 seconds); 3.5 seconds
Alarm Capability
Audible and visual
Other Operational Parameters
Has data logging onboard
Training Required
<1 week training
Training Available
2 to 3 hours online training
Manuals Available
Operator’s manual
Warranties
1 year with extended warranties available
IATA Shipping Restrictions
Yes; Calibration gas cylinder must be shipped per IATA restrictions for compressed gas.