XL3t900
Discontinued: The Thermo Scientific Niton XL3t is a tube-based handheld x-ray fluorescence (XRF) analyzer. The XL3t allows for light element analysis with an attachable helium purge system.
Availability: DISCONTINUED
| Manufacturer |
| Thermo Fisher Scientific, Inc. |
| Product Name |
| XL3t900 |
| Detection Category |
| Chemical |
| Detection Principle |
| Elemental Analysis; |
| Detection Method |
| X-ray Fluorescence; |
| Application |
| Laboratory Analysis; Forensics; |
| Equipment Type |
| Instrument |
| Product Synopsis |
| Discontinued: The Thermo Scientific Niton XL3t is a tube-based handheld x-ray fluorescence (XRF) analyzer. The XL3t allows for light element analysis with an attachable helium purge system. |
| Availability |
| DISCONTINUED |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Hands-on experience, DoD |
| Dimensions |
| 9.60 x 9.05 x 3.75 in (244 x 230 x 95.5 mm) |
| Weight |
| <5 Lbs.; < 3.0 Lbs. (< 1.3 kg) |
| Power Requirements |
| Lithium Battery; Two 4 (or optional 6) cell lithium-ion battery packs |
| Transportability |
| Handheld |
| Ruggedness |
| None; Must be handled carefully, unit has a drop sensor |
| Operating Conditions |
| Avoid extreme temperatures and high humidity |
| Consumables |
| <$1,000/year |
| Calibration Schedule |
| Yes |
| Available Accessories |
| Optional: Portable test stand, stationary test stand, extension pole with tripod stand, welding mask, HotFoot™ hot surface adapter, soil testing guard, internal CCD sample imaging system, variable spot size aperture. |
| Data Analysis Support Equipment |
| Portable test stand, stationary test stand, tripod stand Extension pole Welding mask HotFoot™ hot surface adapter Soil testing guard Internal CCD sample imaging system Variable spot size aperture Mining Kit |
| Communications Interface |
| USB, Bluetooth and RS-232 serial communication |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| >5 years |
| Unit Cost |
| $77,495.00 |
| Other Chemical Targets |
| Programmed to detect elements Mg-U |
| Adaptability |
| Yes; manufacturer can add new targets to detector |
| Sample Introduction |
| Liquid; Solid |
| Sensitivity/Detection Limits |
| ppm |
| Start Up Time (From Cold Start To Sample Ready) |
| 2 minutes |
| Response Time (Sample Application To Output) |
| <5 minutes; 5 to 120 seconds |
| Alarm Capability |
| Visual |
| Software Control |
| Yes |
| Other Operational Parameters |
| Multiple modes for analysis |
| Training Required |
| <1 day training |
| Training Available |
| Yes |
| Manuals Available |
| User manual |
| Warranties |
| 1 year |
| IATA Shipping Restrictions |
| Yes; Compressed gas cylinders must be shipped ground only according to IATA restrictions. |