2008SDH-P 15% CO2 Monitor

Designed for use with a printed circuit board (PCB), or a customer’s microprocessor board. The firmware version depends upon the specific customer interface requirements. An analog unit, the VALTRONICS Model 2008SDH-P is a CO2 sensor with digital signal processing and temperature compensation. The firmware VERSION depends upon the specific customer interface requirements. Each serial numbered sensor is individually gas calibrated and temperature compensated at the factory.

Notify me on updates of this product 

Availability: Commercially Available

Bill Dunlap
vti@val-tronics.com
+1 209 754 0707
3463 Double Springs Rd
Valley Springs, CA 95252
www.val-tronics.com/contact.html
Manufacturer
VTI-Valtronics, Inc.
Product Name
2008SDH-P 15% CO2 Monitor
Detection Category
Chemical
Detection Principle
Molecular Spectroscopy;
Detection Method
Non-Dispersive Infrared (NDIR);
Application
Gas Analysis;
Equipment Type
Sensor
Product Synopsis
Designed for use with a printed circuit board (PCB), or a customer’s microprocessor board. The firmware version depends upon the specific customer interface requirements. An analog unit, the VALTRONICS Model 2008SDH-P is a CO2 sensor with digital signal processing and temperature compensation. The firmware VERSION depends upon the specific customer interface requirements. Each serial numbered sensor is individually gas calibrated and temperature compensated at the factory.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
3.9 x 5 x 1.5 in (100 x 127 x 39 mm)
Weight
<1 lb.; < 0.5 lbs (.23 kg)
Power Requirements
AC/DC Line Power; 24 V DC @ 0.4 amp max (20.0 to 26.0 VDC absolute min/max)
Transportability
Pocket Size
Operating Conditions
Operating temperature: 0 to 50°C (32° to 122°F) Storage temperature: -40 to 70°C (-40 to 158°F) 5 – 95% RH, non-condensing
Consumables
<$1,000/year; Calibration gas, span gas, hydrophobic filter, regulator, flow meter and tubing
Calibration Schedule
Yes, gas calibration every 6 months
Available Accessories
Field calibration kits, RS-232 test board for calibration, Master/Slave jumper JP2 Slave mode, interface connector
Communications Interface
RS-232, serial data input
Shelf Life
>5 years
Unit Cost
$1,062.00
Maintenance Cost
Minimal
Other Chemical Targets
Carbon dioxide
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm; %
Start Up Time (From Cold Start To Sample Ready)
Less than 2 minutes for use and 5 minutes for accuracy
Response Time (Sample Application To Output)
Continuous (<30 seconds); 8 seconds typical
Training Required
<1 day training
Manuals Available
User Manual
Warranties
1 yr
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: