556MPS
The YSI 556 MPS (Multi-Probe System) is a handheld unit with a multi-parameter system. It simultaneously measures dissolved oxygen, conductivity, temperature, and optional pH and ORP. The 1.5 MB memory can store more than 49,000 data sets. Other options include a flow cell and barometer. The internal barometer can be user-calibrated and displayed along with other data, used in dissolved oxygen calibrations, and logged to memory for tracking changes in barometric pressure. Older and more expensive than the ProPlus and it does not measure for ammonium or nitrates.
Availability: Commercially Available
Manufacturer |
| YSI, Inc. |
Product Name |
| 556MPS |
Detection Category |
| Chemical |
Detection Principle |
| Sensors; |
Detection Method |
| Sensors |
Application |
| Water Quality; |
Equipment Type |
| Sensor |
Product Synopsis |
| The YSI 556 MPS (Multi-Probe System) is a handheld unit with a multi-parameter system. It simultaneously measures dissolved oxygen, conductivity, temperature, and optional pH and ORP. The 1.5 MB memory can store more than 49,000 data sets. Other options include a flow cell and barometer. The internal barometer can be user-calibrated and displayed along with other data, used in dissolved oxygen calibrations, and logged to memory for tracking changes in barometric pressure. Older and more expensive than the ProPlus and it does not measure for ammonium or nitrates. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 4.7 in x 9 in (11.9 x 22.9 cm) |
Weight |
| <5 lbs.; 2 lbs (916 g) |
Power Requirements |
| Alkaline Battery; 4 alkaline C-cells |
Transportability |
| Pocket Size |
Ruggedness |
| Waterproof/Resistant |
Operating Conditions |
| 0 to 40°C (operational temperature range) -20 to 30°C (storage range) |
Consumables |
| >$1,000/year; DO electrode module, DO membrane, calibration reagents, buffers and standards, sensors |
Calibration Schedule |
| Yes |
Suggested Routine Maintenance |
| Membrane cap, probe module, sensor and battery replacement |
Communications Interface |
| RS232 |
Shelf Life |
| >5 years |
Unit Cost |
| $3,500.00 |
Maintenance Cost |
| Membrane $56, Replacement probe $250 to $450 |
Other Chemical Targets |
| Measures Dissolved Oxygen, pH, Conductivity, Temperature, and ORP |
Sample Introduction |
| Liquid |
Sensitivity/Detection Limits |
| ppt; ppm; %; mg; 0 to 500% air saturation, 0 to 50 mg/L – dissolved oxygen |
Start Up Time (From Cold Start To Sample Ready) |
| 10-15 minutes (temperature equilibration) |
Response Time (Sample Application To Output) |
| <1 minute |
Software Control |
| Yes |
Training Required |
| <1 week training |
Manuals Available |
| Yes |
Warranties |
| 3 year instrument, 1 year probes and cables |