600XL V2 and 600XLM V2
The YSI 600XL V2 compact sondes measure multiple parameters simultaneously, including: Temperature Specific Conductance, Salinity, Resistivity, TDS Conductivity, pH, ORP, Depth or Level. (Powered externally) The YSI 600XLM V2 is an economical logging system for long-term, in situ monitoring, profiling, and spot sampling. It will log all parameters at programmable intervals and store 150,000 readings. At one-hour intervals, the instrument will log data for about 75 days utilizing its own power source. The 600XL V2 can also be used in the same manner. It is powered with batteries.
Availability: Commercially Available
Manufacturer |
| YSI, Inc. |
Product Name |
| 600XL V2 and 600XLM V2 |
Detection Category |
| Chemical |
Detection Principle |
| Sensors; |
Detection Method |
| Sensors |
Application |
| Water Quality; |
Equipment Type |
| Sensor |
Product Synopsis |
| The YSI 600XL V2 compact sondes measure multiple parameters simultaneously, including: Temperature Specific Conductance, Salinity, Resistivity, TDS Conductivity, pH, ORP, Depth or Level. (Powered externally) The YSI 600XLM V2 is an economical logging system for long-term, in situ monitoring, profiling, and spot sampling. It will log all parameters at programmable intervals and store 150,000 readings. At one-hour intervals, the instrument will log data for about 75 days utilizing its own power source. The 600XL V2 can also be used in the same manner. It is powered with batteries. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 1.65 x 21.3 in (49 x 541 mm) |
Weight |
| <5 lbs.; 1.5 lbs, 0.69 kg |
Power Requirements |
| AC/DC Line Power; 12 V DC |
Transportability |
| Handheld |
Operating Conditions |
| Can operate in fresh, sea or polluted water -5 to 50°C (operating temperature) -40 to 60° C (storage temperature sonde and sensors except pH, pH/ORP) -10 to 60° C (storage temperature pH, pH/ORP |
Consumables |
| <$1,000/year; Sonde weights, calibration and buffer solution, maintenance kit, anti-fouling plugs and screen, pH sensors |
Calibration Schedule |
| Pre and post sampling calibrations required |
Available Accessories |
| $4,400 (with the depth sensor) |
Data Analysis Support Equipment |
| EcoWatch PC, version 3.18 |
Communications Interface |
| RS-232, SDI-12 connections |
Unit Cost |
| $4,000.00 |
Other Chemical Targets |
| Measure temperature, conductivity, salinity, specific conductance, resistivity, TDS, depth or shallow vented level, pH, ORP |
Sample Introduction |
| Liquid |
Sensitivity/Detection Limits |
| ppt; %; mg; 0 to 500%, 0 to 50 mg/L - dissolved oxygen 0 to 100 mS/cm – conductivity 0 to 70 ppt – salinit |
Known Interferents/Inhibitors |
| Animals, debris, fouling, and air bubbles can interfere with measurements |
Start Up Time (From Cold Start To Sample Ready) |
| 5 to 15 minutes, depending on test. Also allow a couple of minutes for the sonde to equilibrate in the sample |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
Software Control |
| PC |
Training Required |
| <1 day training |
Manuals Available |
| Yes |
Warranties |
| 3 year instrument, 2 year for cable and probe |