MINICAMS 3500/2010
The MINICAMS® Series is an automatic, near-real-time continuous air monitoring system using gas chromatography and sample collection with a solid-adsorbent preconcentrator or fixed-volume sample loop. The MINICAMS collects an air sample, performs an analysis, and reports the result. Three different Plug-In GC Modules allow configurations to maximize selectivity and sensitivity for monitoring all chemical warfare (CW) agents. Multiple MINICAMS can be networked to provide a facility-wide Air Monitoring System.
Availability: DISCONTINUED
Greg Houston
Sales Manager
+1 205 733 6900 Ext. 204
2148 Pelham Parkway, Building 400
Pelham, AL 35124
USA
|
|
www.oico.com
Manufacturer |
| OI Analytical |
Product Name |
| MINICAMS 3500/2010 |
Detection Category |
| Chemical |
Detection Principle |
| Chromatography; Sensors; |
Detection Method |
| Flame Photometric Detection (FPD); Pulsed Flame Photometric Detector (PFPD); Flame Ionization Detection (FID); Photoionization Detection; Gas Chromatography; |
Application |
| Gas Analysis; Laboratory Analysis; |
Equipment Type |
| Instrument |
Product Synopsis |
| The MINICAMS® Series is an automatic, near-real-time continuous air monitoring system using gas chromatography and sample collection with a solid-adsorbent preconcentrator or fixed-volume sample loop. The MINICAMS collects an air sample, performs an analysis, and reports the result. Three different Plug-In GC Modules allow configurations to maximize selectivity and sensitivity for monitoring all chemical warfare (CW) agents. Multiple MINICAMS can be networked to provide a facility-wide Air Monitoring System. |
Availability |
| DISCONTINUED |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 12 x 12 x 10 in (305 x 305 x 254 mm) |
Weight |
| <30 lbs.; 18 lbs (8.2 kg) |
Power Requirements |
| AC/DC Line Power; 120 VAC |
Transportability |
| Benchtop/Fixed; Small Footprint |
Ruggedness |
| None; Not militarized, drop sensitive |
Operating Conditions |
| 5 to 40°C (41 to 104°F) |
Consumables |
| >$1,000/year; Air, high purity hydrogen for FPD and PFPD, helium carrier gas |
Solvents/Reagents |
| None |
Calibration Schedule |
| Calibrate for specific needs |
Suggested Routine Maintenance |
| Columns, detectors, concentrators |
Data Analysis Support Equipment |
| Continuous sampling system Stream selection systems Heated sample lines Sample flow controller Low volume sampler |
Communications Interface |
| RS232 RS485 |
Shelf Life |
| >5 years |
Unit Cost |
| $44,820.00 |
Maintenance Cost |
| $2,500 per year |
Tested For Chemical Agents |
| Nerve agent, blister agents |
Tested For ITF-25 TIC/TIMs |
| Phosgene, cyanogen chloride, chloropicrin, methylene chloride, vinyl chloride, phosphine, DMMP, malathion benzene, nitrobenzene, toluene, ethylene oxide, acetonitrile |
Other Chemical Targets |
| Yes |
Adaptability |
| Yes |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| ng |
Start Up Time (From Cold Start To Sample Ready) |
| 10 minutes |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
Alarm Capability |
| Integral audible and visual alarm indicators |
Software Control |
| Chrom-NET |
Other Operational Parameters |
| Programmable for specific needs |
Training Required |
| <1 week training |
Training Available |
| Different training options available |
Warranties |
| 1 year parts and labor |
IATA Shipping Restrictions |
| Yes; Compressed gas cylinders must be shipped by ground only per IATA regulations. |