2020 Combo Pro
The 2020ComboPRO is a photoionization detector (PID) with an extended range of 0.1 to 10,000 ppm. The 2020 ComboPRO measures a wide variety of chemicals for environmental, industrial hygiene, and emergency response applications. Previously sold under the same name by PhotoVac, which was acquired by INFICON in 2011.
Availability: DISCONTINUED
Manufacturer |
| INFICON |
Product Name |
| 2020 Combo Pro |
Detection Category |
| Chemical |
Detection Principle |
| Sensors; |
Detection Method |
| Photoionization Detection; |
Application |
| Emergency Response; Gas Analysis; |
Equipment Type |
| Instrument |
Product Synopsis |
| The 2020ComboPRO is a photoionization detector (PID) with an extended range of 0.1 to 10,000 ppm. The 2020 ComboPRO measures a wide variety of chemicals for environmental, industrial hygiene, and emergency response applications. Previously sold under the same name by PhotoVac, which was acquired by INFICON in 2011. |
Availability |
| DISCONTINUED |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 9 x 4.25 x 3 in (22.9 x 10.8 x 7.6 cm) |
Weight |
| <5 lbs.; 1.9 lbs (0.86 kg) |
Power Requirements |
| NiMH Battery; AC/DC Line Power; 7.2 V field-replaceable NiCad or AC operation from charger |
Transportability |
| Handheld |
Ruggedness |
| None |
Operating Conditions |
| 0 to 50°C (32 to 122°F) ; 0 to 95% RH (non-condensing) |
Consumables |
| <$1,000/year; Gas, filters, ultraviolet lamp (after 2,000 hr) |
Calibration Schedule |
| Yes |
Suggested Routine Maintenance |
| Lamp replacement $325 |
Communications Interface |
| RS-232, 9600 baud, 8 data bits, no parity for connection to Windows-based PC |
Shelf Life |
| <5 years; Gas cylinders have a 1 to 2 year shelf life |
Unit Cost |
| $3,200.00 |
Maintenance Cost |
| ~ $200 per year with calibration gas and filters |
Tested For ITF-25 TIC/TIMs |
| Non-specific detection of ammonia, arsine, carbon disulfide, ethylene oxide, hydrogen sulfide, phosgene, acrolein, acrylonitrile, allyl alcohol, and phosphine. |
Other Chemical Targets |
| Non-specific detection of aromatics, unsaturated hydrocarbons, chlorinated hydrocarbons, ketones, alcohols, organic fuels |
Adaptability |
| No; cannot detect or add new targets |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| ppm; 0.1 to 10,000 ppm |
Start Up Time (From Cold Start To Sample Ready) |
| 1 minute |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds); 3 seconds |
Alarm Capability |
| Audible and visual |
Software Control |
| RS-232, 9600 baud, 8 data bits, no parity for connection to Windows-based PC |
Training Required |
| <1 day training |
Training Available |
| Yes |
Manuals Available |
| Operator’s manual |
Warranties |
| 1 year |