Voyager
The Voyager is a portable GC with rechargeable and field-replaceable batteries that allow up to eight hours of field use, or the option to operate off external AC or DC sources. Voyager's analytical engine is composed of a built-in three-column configuration with an isothermal oven for fast GC analysis for up to 40 factory-programmed EPA listed VOCs. The Voyager has a miniaturized PID/ECD dual detection system. Chromatograms and/or tabular results are easily viewed in the field using the built-in backlit LCD screen. Previously sold under the same name by PhotoVac, which was acquired by INFICON in 2011. The Explorer has replaced this product.
Availability: DISCONTINUED
Manufacturer |
| INFICON |
Product Name |
| Voyager |
Detection Category |
| Chemical |
Detection Principle |
| Chromatography; |
Detection Method |
| Gas Chromatography; |
Application |
| Emergency Response; Gas Analysis; |
Equipment Type |
| Instrument |
Product Synopsis |
| The Voyager is a portable GC with rechargeable and field-replaceable batteries that allow up to eight hours of field use, or the option to operate off external AC or DC sources. Voyager's analytical engine is composed of a built-in three-column configuration with an isothermal oven for fast GC analysis for up to 40 factory-programmed EPA listed VOCs. The Voyager has a miniaturized PID/ECD dual detection system. Chromatograms and/or tabular results are easily viewed in the field using the built-in backlit LCD screen. Previously sold under the same name by PhotoVac, which was acquired by INFICON in 2011. The Explorer has replaced this product. |
Availability |
| DISCONTINUED |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 15.4 × 3 × 2 in (39 × 7.6 × 5.1 cm) |
Weight |
| <30 lbs.; 14.96 lbs (6.8 kg) |
Power Requirements |
| NiMH Battery |
Transportability |
| Person-Portable |
Ruggedness |
| None |
Operating Conditions |
| 0 to 40°C (32 to 105°F); 0 to 100% RH |
Consumables |
| <$1,000/year; Carrier gas |
Calibration Schedule |
| Every 8 hours |
Available Accessories |
| Battery pack, ac adapter, communication cable kit, 10 fluorophore membrane filters, carrying strap, carrier gas connection kit, tool kit, and site chart LX software |
Data Analysis Support Equipment |
| PC and software |
Communications Interface |
| A RS–232 cable allows data to be sent to a PC using Photovac Sitechart software |
Unit Cost |
| $24,000.00 |
Tested For ITF-25 TIC/TIMs |
| Yes, includes: Ammonia, arsine, carbon disulfide, ethylene oxide, hydrogen sulfide, phosgene, acrolein, acrylonitrile, allyl alcohol, and phosphine. |
Other Chemical Targets |
| Yes |
Adaptability |
| Yes; user can add new targets to detector with support |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| ppb; ppm |
Known Interferents/Inhibitors |
| Has few noncritical interferences |
Start Up Time (From Cold Start To Sample Ready) |
| Less than 20 minutes |
Response Time (Sample Application To Output) |
| <15 minutes; 5 minutes to 15 minutes |
Alarm Capability |
| Audible and Visual |
Software Control |
| On-board; PC |
Training Required |
| <1 week training |
Training Available |
| Yes |
Manuals Available |
| User manual and site chart software manual |
Warranties |
| 1 year |
IATA Shipping Restrictions |
| Yes; Compressed gas cylinders must be shipped ground only according to IATA restrictions. |