Voyager

The Voyager is a portable GC with rechargeable and field-replaceable batteries that allow up to eight hours of field use, or the option to operate off external AC or DC sources. Voyager's analytical engine is composed of a built-in three-column configuration with an isothermal oven for fast GC analysis for up to 40 factory-programmed EPA listed VOCs. The Voyager has a miniaturized PID/ECD dual detection system. Chromatograms and/or tabular results are easily viewed in the field using the built-in backlit LCD screen. Previously sold under the same name by PhotoVac, which was acquired by INFICON in 2011. The Explorer has replaced this product.

Notify me on updates of this product 

Availability: DISCONTINUED

Rebecca Robertson
DOD/DHS Account Manager
rebecca.robertson@inficon.com
+1 315 434 2580
Two Technology Place
East Syracuse, NY 13057
www.inficon.com
Manufacturer
INFICON
Product Name
Voyager
Detection Category
Chemical
Detection Principle
Chromatography;
Detection Method
Gas Chromatography;
Application
Emergency Response; Gas Analysis;
Equipment Type
Instrument
Product Synopsis
The Voyager is a portable GC with rechargeable and field-replaceable batteries that allow up to eight hours of field use, or the option to operate off external AC or DC sources. Voyager's analytical engine is composed of a built-in three-column configuration with an isothermal oven for fast GC analysis for up to 40 factory-programmed EPA listed VOCs. The Voyager has a miniaturized PID/ECD dual detection system. Chromatograms and/or tabular results are easily viewed in the field using the built-in backlit LCD screen. Previously sold under the same name by PhotoVac, which was acquired by INFICON in 2011. The Explorer has replaced this product.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
15.4 × 3 × 2 in (39 × 7.6 × 5.1 cm)
Weight
<30 lbs.; 14.96 lbs (6.8 kg)
Power Requirements
NiMH Battery
Transportability
Person-Portable
Ruggedness
None
Operating Conditions
0 to 40°C (32 to 105°F); 0 to 100% RH
Consumables
<$1,000/year; Carrier gas
Calibration Schedule
Every 8 hours
Available Accessories
Battery pack, ac adapter, communication cable kit, 10 fluorophore membrane filters, carrying strap, carrier gas connection kit, tool kit, and site chart LX software
Data Analysis Support Equipment
PC and software
Communications Interface
A RS–232 cable allows data to be sent to a PC using Photovac Sitechart software
Unit Cost
$24,000.00
Tested For ITF-25 TIC/TIMs
Yes, includes: Ammonia, arsine, carbon disulfide, ethylene oxide, hydrogen sulfide, phosgene, acrolein, acrylonitrile, allyl alcohol, and phosphine.
Other Chemical Targets
Yes
Adaptability
Yes; user can add new targets to detector with support
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppb; ppm
Known Interferents/Inhibitors
Has few noncritical interferences
Start Up Time (From Cold Start To Sample Ready)
Less than 20 minutes
Response Time (Sample Application To Output)
<15 minutes; 5 minutes to 15 minutes
Alarm Capability
Audible and Visual
Software Control
On-board; PC
Training Required
<1 week training
Training Available
Yes
Manuals Available
User manual and site chart software manual
Warranties
1 year
IATA Shipping Restrictions
Yes; Compressed gas cylinders must be shipped ground only according to IATA restrictions.