GCMS-QP2010 Ultra

There is increasing public interest in the analysis of trace compounds that contribute to environmental pollution, affect human health and in research related to novel compounds. Reducing running costs and lessening the impact on the environment by increasing analytical efficiency and decreasing power consumption are universal goals. The GCMS-QP2010 Ultra was developed by engineers who accepted the challenge to meet these needs.

Notify me on updates of this product 

Availability: Commercially Available

Greg Feldman
Sr. Field Sales Engineer
gsfeldman@shimadzu.com
1-913-888-9449, Ext. 1270
8052 Reeder Street
Lenexa, KS 66214
Midwest Regional Office
Jason Kuchar, Ph. D.
Life Science account Manager
jakuchar@shimadzu.com
1-913-888-9449, Ext. 1265
8052 Reeder Street
Lenexa, KS 66214
Midwest Regional Office
www.ssi.shimadzu.com
Manufacturer
Shimadzu
Product Name
GCMS-QP2010 Ultra
Detection Category
Chemical; Explosives
Detection Principle
Chromatography; Spectrometry;
Detection Method
Gas Chromatography; Quadrupole Mass Spectrometry;
Application
Laboratory Analysis;
Equipment Type
Instrument
Product Synopsis
There is increasing public interest in the analysis of trace compounds that contribute to environmental pollution, affect human health and in research related to novel compounds. Reducing running costs and lessening the impact on the environment by increasing analytical efficiency and decreasing power consumption are universal goals. The GCMS-QP2010 Ultra was developed by engineers who accepted the challenge to meet these needs.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Weight
>50 Lbs.
Power Requirements
AC/DC Line Power
Noise Produced
None
Transportability
Benchtop/Fixed
Ruggedness
Indoor Use Only
Operating Conditions
Indoor Use Only
Consumables
>$1,000/year
Solvents/Reagents
Standard solutions
Data Analysis Support Equipment
Software, PC
Expected Operational Life
Indefinite
Shelf Life
>5 years
Tested For Chemical Agents
Amenable based on Technology
Tested For ITF-25 TIC/TIMs
Amenable based on Technology
Tested For Explosives
Amenable based on Technology
Tested For Narcotics
Amenable based on Technology
Other Chemical Targets
Amenable based on Technology
Tested For Biological Agents
No
Other Biological Targets
No
Radiological Targets
No
Sample Introduction
Liquid
Sensitivity/Detection Limits
ng
Response Time (Sample Application To Output)
>15 minutes
Total Run Time
None
Alarm Capability
PC
Training Required
>1 week training
Training Available
Yes
Manuals Available
Yes
Warranties
Yes
Please enter contact info.
Email Address: 
Company: 
Name: 