Eagle-2
The Eagle-2 is a handheld 6-gas monitor with an active internal sampling pump. Features include a PID sensor for detecting high or low ppm levels (0-50 & 0-2,000) of VOC gases; % volume capability for CH4 and H2 using a TC (thermal conductivity) sensor; ppm or LEL hydrocarbon detection at the push of a button; infrared sensors for CO2 (ppm or % volume), methane or hydrocarbons in LEL and % volume ranges. Optional LEL / ppm H2 specific sensor, methane elimination feature for environmental applications, and a variety of toxic gases.
Availability: Commercially Available
Manufacturer |
| RKI Instruments |
Product Name |
| Eagle-2 |
Detection Category |
| Chemical |
Detection Principle |
| Sensors; |
Detection Method |
| Photoionization Detection; Electrochemical Detection; |
Application |
| Emergency Response; Gas Analysis; |
Product Model Number |
| Eagle-2 |
Equipment Type |
| Instrument |
Product Synopsis |
| The Eagle-2 is a handheld 6-gas monitor with an active internal sampling pump. Features include a PID sensor for detecting high or low ppm levels (0-50 & 0-2,000) of VOC gases; % volume capability for CH4 and H2 using a TC (thermal conductivity) sensor; ppm or LEL hydrocarbon detection at the push of a button; infrared sensors for CO2 (ppm or % volume), methane or hydrocarbons in LEL and % volume ranges. Optional LEL / ppm H2 specific sensor, methane elimination feature for environmental applications, and a variety of toxic gases. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 9.5 x 5.25 x 5.9 in. (24 x 13 x 15 cm) |
Weight |
| <5 lbs.; 3.8 lbs (1.7 kg) |
Power Requirements |
| Alkaline Battery; NiMH Battery; 4 alkaline or NiMH Size C batteries; 16 hours using alkaline, 18 hours using NiMH. |
Noise Produced |
| 95 dB alarm |
Transportability |
| Handheld |
Ruggedness |
| Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; Vibration/Shock; IP-64 approval; can operate in 2 in. of water without leakage. |
Operating Conditions |
| -20 to 50°C (-4 to 122°F), 0 to 95% RH, non-condensing |
Consumables |
| <$1,000/year; Calibration gases, filters, sensors |
Calibration Schedule |
| Depends on use; weekly or monthly under normal use. |
Suggested Routine Maintenance |
| Change batteries, sensors, and H2S filter disk as needed. See vendor website for frequency of replacement. |
Available Accessories |
| Dilution fitting (50:50); battery charger; extension hoses |
Data Analysis Support Equipment |
| Data logging capability with 3600 data point capacity; log time range of 10 to 300 hours |
Communications Interface |
| IrDA or USB with IrDA adapter |
Expected Operational Life |
| 10 years |
Shelf Life |
| >5 years |
Unit Cost |
| $3,200.00 |
Maintenance Cost |
| $1,000/year (est.) for replacement sensors and calibration gases |
Other Chemical Targets |
| Combustible gases (as %LEL), PPM methane, O2, CO, and H2S, NH3, AsH3, CL2, HCN, PH3, SO2. PID sensor: VOCs |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| ppm; %LEL |
Start Up Time (From Cold Start To Sample Ready) |
| 1 to 2 minutes |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
Total Run Time |
| Continuous |
Alarm Capability |
| Audible and Visual |
Training Required |
| <1 day training |
Training Available |
| No |
Manuals Available |
| Yes |
Warranties |
| 2 years material and workmanship |
Approved Vendors |
| Multiple |
Data File Type Format |
| Proprietary |