D3S NET

The D3S NET radiation detector is a radioisotope identification device (RIID) for Gamma emitting isotope identification and Neutron detection. The data collected by this radiation detector is not only shown to the user via the mobile phone app (on the phone that comes with the detector) but also sent to a central control screen showing data from every other SIGMA enabled detector on the network. The D3S NET detector unit houses larger detectors that provide identification of isotopes in seconds, alerting the user and your command center of Gamma isotope source, dose and any Neutron detection.

Notify me on updates of this product 

Availability: Commercially Available

sales@kromek.com
1 (626) 593-5118
2934 East Garvey Avenue South, Suite 104 West Covina CA 91791 USA
USA
Trevor Nicholls
Director of Sales and Marketing
trevor.nicholls@kromek.com
USA
www.kromek.com
Manufacturer
Kromek Group plc
Product Name
D3S NET
Detection Category
Radiological/Nuclear;
Detection Principle
Scintillation Detectors;
Detection Method
Scintillation Detectors;
Application
Survey meter;Personal Radiation Detectors;
Product Model Number
D3S NET
Equipment Type
Instrument
Product Synopsis
The D3S NET radiation detector is a radioisotope identification device (RIID) for Gamma emitting isotope identification and Neutron detection. The data collected by this radiation detector is not only shown to the user via the mobile phone app (on the phone that comes with the detector) but also sent to a central control screen showing data from every other SIGMA enabled detector on the network. The D3S NET detector unit houses larger detectors that provide identification of isotopes in seconds, alerting the user and your command center of Gamma isotope source, dose and any Neutron detection.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Supporting Documentation
Docs: D3S NET Brochure.pdf;
Dimensions
5 x 3 x 0.8 in (120 x 80 x 20 mm)
Weight
<1 lb.; 0.33 lbs (150g)
Power Requirements
Lithium Battery; 1100mAh Lithium polymer (12 hours)
Transportability
Pocket Size
Ruggedness
Extreme Temperatures/Humidity; ANSI N42.32
Operating Conditions
-20 to 50°C (-4 to 122°F)
Consumables
None
Calibration Schedule
SiPM array LED auto-calibration
Data Analysis Support Equipment
Cell phone, PC
Communications Interface
Mini-USB, bluetooth
Expected Operational Life
Indefinite
Radiological Targets
Gamma, neutron
Number of Library Entries
416 radionuclides
Adaptability
Yes; user can add new targets to detector with support
Sample Introduction
Radioactive Particle
Sensitivity/Detection Limits
CPS; µSv; dose rate: Up to 15µSv/h at 662keV
Start Up Time (From Cold Start To Sample Ready)
Seconds to minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Continuous
Alarm Capability
Audible, visual, vibration
Software Control
Yes
Other Operational Parameters
Energy range: 30 keV to 3.0 MeV
Training Required
<1 day training
Training Available
No
Manuals Available
User's Manual
Warranties
1 year
IATA Shipping Restrictions
Yes; Lithium ion battery
Data File Type Format
SPE, CSV
Please enter contact info.
Email Address: 
Company: 
Name: 