Griffin™ 400

The Griffin™ 400 Gas Chromatograph/Mass Spectrometer (GC/MS) is capable of confirming the presence of explosives, chemical warfare agents (CWAs), industrial chemicals and organic compounds, including both volatile and semi-volatile components. In addition, the Griffin 400 supports a number of sample inlets.

Notify me on updates of this product 

Availability: DISCONTINUED

Toby Kennedy
DoD Sales and BD Manager
toby.kennedy@teledyneflir.com
580-761-7184
27713 SW Parkway Avenue
Wilsonville, OR 97083
The Americas, EMEA, APAC
Contact for pricing, availability and 3rd party vendors
https://www.flir.com/browse/government-defense/cbrne-detectors/
Manufacturer
Teledyne FLIR Detection, Inc.
Product Name
Griffin™ 400
Detection Category
Chemical; Explosives
Detection Principle
Spectrometry; Chromatography;
Detection Method
Ion Trap Mass Spectrometry; Gas Chromatography;
Application
Laboratory Analysis; Bulk Analysis; Screening; Forensics;
Equipment Type
Instrument
Product Synopsis
The Griffin™ 400 Gas Chromatograph/Mass Spectrometer (GC/MS) is capable of confirming the presence of explosives, chemical warfare agents (CWAs), industrial chemicals and organic compounds, including both volatile and semi-volatile components. In addition, the Griffin 400 supports a number of sample inlets.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
Market Entry Date
2004
User Feedback Sources
Indifferent/No user feedback
Dimensions
19.2 × 19.2 × 18.0 in (480 x 480 x 460 mm)
Weight
>50 Lbs.; 82 Lbs. (37 kg)
Power Requirements
AC/DC Line Power; 115/220 V AC; 130 W continuous power
Transportability
Benchtop/Fixed; Small Footprint
Ruggedness
Vibration/Shock; To enhance its mobile capabilities, the analytical components of the Griffin 400 have been shock mounted and placed on a durable and rugged chassis. This shock mounting system makes the Griffin 400 operational in more aggressive environments such as vehicles and mobile analytical labs that are taken directly to the site of interest.
Operating Conditions
41 to 104 °F (5 to 40 °C); <85% relative humidity
Consumables
<$1,000/year; GC carrier gas
Calibration Schedule
Yes; auto calibrates
Suggested Routine Maintenance
Typical for MS
Communications Interface
Data is Compatible with NIST, AMDIS. Ethernet TCP/IP
Maintenance Cost
N/A
Tested For Chemical Agents
Yes
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
Yes – most organic explosives
Other Chemical Targets
Yes
Adaptability
Yes; user can add new targets to detector with support
Sample Introduction
Liquid; Vapor/Gas; Solid
Sensitivity/Detection Limits
ppt
Known Interferents/Inhibitors
MS/MS provides additional specificity for target chemicals vs. conventional quadrupole GC/MS.
Response Time (Sample Application To Output)
<15 minutes; Chemicals elute from the column at different times, which means analysis method times may vary. Result times also can depend on the sampling tool utilized. Most GRIFFIN GC/MS customers use test methods that achieve target identification within 3-15 minutes.
Alarm Capability
Visual alarms
Software Control
Laptop computer. Two-level user software choices tailored for operator skill and analysis requirements. Griffin System Software NIST and AMDIS mass spectral libraries are included, as well as user-defined library capabilities.
Training Required
<1 week training
Training Available
Yes
Manuals Available
Yes
ITAR/EAR Export Regulations
Yes; These products are controlled for export under US Department of Commerce (DOC), Export Administration Regulations (EAR). U.S. Government authorization may be required for export.
IATA Shipping Restrictions
Yes, compressed gas cylinders must adhere to IATA regulations
Approved Vendors
N/A