Griffin™ 625

The GRIFFIN 625 provides continuous indoor air monitoring and detection for building and facilities protection. It detects chemical contaminants in vapor, with response times of less than 15 seconds. Direct Sampling Mass Spectrometry provides sensitive yet selective analysis, with the ability to monitor and report positive hits in real time for a broad range of chemical targets, including Chemical Warfare Agents and Toxic Industrial Chemicals. The GRIFFIN 625 utilizes ion trap technology, providing the ability to perform multi-dimensional analysis or MS/MS. Equipped with an onboard computer, the GRIFFIN 625 controls, stores data, and handles communication. The GRIFFIN 625 alarms based on programmed target compound entries. As new targets are identified, they may be added to the library.

Notify me on updates of this product 

Availability: Commercially Available

Toby Kennedy
DoD Sales and BD Manager
toby.kennedy@teledyneflir.com
580-761-7186
27715 SW Parkway Avenue
Wilsonville, OR 97085
The Americas, EMEA, APAC
Contact for pricing, availability and 3rd party vendors
https://www.flir.com/browse/government-defense/cbrne-detectors/
Manufacturer
Teledyne FLIR Detection, Inc.
Product Name
Griffin™ 625
Detection Category
Chemical
Detection Principle
Spectrometry;
Detection Method
Ion Trap Mass Spectrometry; Tandem Mass Spectrometry (MS/MS);
Application
Gas Analysis;
Product Model Number
Multiple Based on Selected Options - Not Specified
Equipment Type
Instrument
Product Synopsis
The GRIFFIN 625 provides continuous indoor air monitoring and detection for building and facilities protection. It detects chemical contaminants in vapor, with response times of less than 15 seconds. Direct Sampling Mass Spectrometry provides sensitive yet selective analysis, with the ability to monitor and report positive hits in real time for a broad range of chemical targets, including Chemical Warfare Agents and Toxic Industrial Chemicals. The GRIFFIN 625 utilizes ion trap technology, providing the ability to perform multi-dimensional analysis or MS/MS. Equipped with an onboard computer, the GRIFFIN 625 controls, stores data, and handles communication. The GRIFFIN 625 alarms based on programmed target compound entries. As new targets are identified, they may be added to the library.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
Market Entry Date
2012
User Feedback Sources
Military CBRNE teams, Buildings, Navy Ships
Dimensions
17 x 19 x 10.4 in (45 x 48 x 26 cm)
Weight
<50 Lbs.; 40 Lbs. (18.1 kg)
Power Requirements
AC/DC Line Power; Standard AC power: 110-240 VAC, 50/60 Hz
Noise Produced
Low
Transportability
Benchtop/Fixed
Ruggedness
Indoor use only
Operating Conditions
0 to 40°C (32 to 104°F); 95% RH non-condensing
Consumables
None
Calibration Schedule
On-board standards for quantitative and mass calibration
Suggested Routine Maintenance
Annual maintenance
Data Analysis Support Equipment
Integrated Data analysis
Communications Interface
2 USB ports and an Ethernet port
Expected Operational Life
Indefinite
Shelf Life
>5 years
Maintenance Cost
Minimal
Tested For Chemical Agents
Yes
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
Yes
Tested For Narcotics
Yes
Other Chemical Targets
Many other chemicals are amenable to MS, providing they are in vapor phase
Number of Library Entries
>30
Adaptability
Yes; user can add new targets to detector with support
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ng
False Positive Rates
Very low
False Negative Rates
Very low
Start Up Time (From Cold Start To Sample Ready)
<30 minutes
Response Time (Sample Application To Output)
<1 minute; 30 seconds
Total Run Time
30 seconds
Alarm Capability
Yes, audible and visual
Software Control
On-board
Other Operational Parameters
Remote operation and remote diagnostics.
Training Required
<1 day training
Training Available
Operator (1-2 days), Developer (2 days) and Full System Maintenance (3-5 days) Level Training Certifications are available.
Manuals Available
Yes; Operator's Manual and Quick Start Guide
Warranties
Standard 1 Year Warranty included; Extended Warranty options are available
ITAR/EAR Export Regulations
Yes; These products are controlled for export under US Department of Commerce (DOC), Export Administration Regulations (EAR). U.S. Government authorization may be required for export.
IATA Shipping Restrictions
Yes; Compressed gas cylinders must be shipped ground only according to IATA restrictions
Data File Type Format
Internal format
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: