A/DAM-SVS

Combination system for analysis if air, liquid, and solid samples in the field for detection of CWAs and TICs. Made up from the following instruments: IACEM 980, 6852 GC, and 5973N MSD. Entire sample pathway is closed so potentially toxic vapors can’t escape into the laboratory or mobile platform.

Notify me on updates of this product 

Availability: DISCONTINUED

+1 610 932 3636
465 Limestone Road, P.O. Box 277
Oxford, PA 19363-0277
USA
www.cdsanalytical.com
Manufacturer
CDS Analytical, Inc.
Product Name
A/DAM-SVS
Detection Category
Chemical
Detection Principle
Chromatography; Spectrometry; Sensors; Thermal Analysis;
Detection Method
Gas Chromatography; Flame Photometric Detection (FPD);
Application
Laboratory Analysis; Gas Analysis;
Equipment Type
Instrument
Product Synopsis
Combination system for analysis if air, liquid, and solid samples in the field for detection of CWAs and TICs. Made up from the following instruments: IACEM 980, 6852 GC, and 5973N MSD. Entire sample pathway is closed so potentially toxic vapors can’t escape into the laboratory or mobile platform.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
20 x 39 x 22 in (51 x 99 x 56 cm)
Weight
>50 lbs.; 200 lbs (90.7 kg)
Power Requirements
AC/DC Line Power; 120 V AC, 20 amps
Transportability
Mounted
Operating Conditions
Designed for use in a controlled environment 59° to 95°F.
Consumables
>$1,000/year; Chromatograph supplies ferrules, GC columns, nuts, carrier gas, etc. Mass spectrometer supplies: forepump oil, filaments, gaskets, o-rings, etc.
Calibration Schedule
Yes. Mass calibration typically performed daily. System must be also calibrated with standard reference solutons of target analytes to verify GC retention time and analyte response.
Suggested Routine Maintenance
Routine preventive maintenance required for optimal performance. Replace filament, change roughing pump oil.
Data Analysis Support Equipment
Liquid autosampler, DAAMS autosampler
Communications Interface
Wireless LAN interface with ChemStation allows for remote operation
Shelf Life
>5 years; Product lifetime indefinite with routine maintenance
Unit Cost
$150,000.00
Maintenance Cost
Est. 5 to $10K per year
Tested For Chemical Agents
GA, GB, GD, GF, VX, HD, HN, L tested on similar MSD systems. Other CWA also tested
Tested For ITF-25 TIC/TIMs
Most organic compounds
Tested For Explosives
Most organic explosives
Other Chemical Targets
Applicable to all organic compounds amenable to GC
Adaptability
Yes
Sample Introduction
Liquid
Sensitivity/Detection Limits
ppt
Known Interferents/Inhibitors
GC/MS is a highly selective technique for identification of organic compounds when used by a skilled operator, with low false positive/negative rates for target analytes. False IDs are more likely for unknowns (nontargets) since GC retention times cannot be compared to reference RTs. Additional selectivity for CWAs provided by FPD detector (sensitive to P and S only).
Start Up Time (From Cold Start To Sample Ready)
30 minutes minimum time to reach operating temperatures and pressure. 2 to 8 hr for optimal performance.
Response Time (Sample Application To Output)
>15 minutes; 5 to 45 minutes, depending on target chemical and method
Alarm Capability
Visual
Software Control
Agilent ChemStation data acquisition software
Other Operational Parameters
Entire system is mounted on a steel plate for moving from a fixed laboratory to a mobile platform. Entire sample pathway is closed; no effluent gases can escape from any components into the atmosphere during analysis.
Training Required
<1 week training
Training Available
Available from MFR
Manuals Available
Operator’s manual on CD
IATA Shipping Restrictions
Yes; Compressed gas cylinders must be shipped ground only according to IATA restrictions.