In-Flight Explosives Detection Kit
The In-Flight Explosives Detection Kit, (IFED), comes with five separate detectors for explosives and explosive precursors. The detectors are Nitro-Pen, On-The-Spot, Verifier, Gel-Ox and Acid Test. The IFED contains no harmful solvents or aerosols and can be used safely on-board aircraft, even in flight. It was designed to reduce the significant cost of re-routing aircraft and associated delays caused when suspicious substances are found during aircraft flights.
Availability: Commercially Available
| Manufacturer |
| Appealing Products, Inc. DBA ChemSee.com |
| Product Name |
| In-Flight Explosives Detection Kit |
| Detection Category |
| Chemical; Explosives |
| Detection Principle |
| Colorimetric; |
| Detection Method |
| Colorimetric; |
| Application |
| Emergency Response; Screening; Bulk Analysis; Trace Analysis; |
| Product Model Number |
| IFED-02 |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The In-Flight Explosives Detection Kit, (IFED), comes with five separate detectors for explosives and explosive precursors. The detectors are Nitro-Pen, On-The-Spot, Verifier, Gel-Ox and Acid Test. The IFED contains no harmful solvents or aerosols and can be used safely on-board aircraft, even in flight. It was designed to reduce the significant cost of re-routing aircraft and associated delays caused when suspicious substances are found during aircraft flights. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 10 x 7 x 3 in (25 x 18 x 8 cm) |
| Weight |
| <1 lb.; 14.5 oz (410 g) |
| Power Requirements |
| None |
| Transportability |
| Handheld |
| Consumables |
| <$1,000/year; Collections Swabs; Detection tab |
| Expected Operational Life |
| 6 months |
| Shelf Life |
| <6 months |
| Unit Cost |
| $96.95 |
| Tested For Explosives |
| Explosive Residues of: Nitro-Organics; Nitramines; Inorganic Nitrates (Z-Pad); Explosive Residues of: Inorganic Nitrates on Smooth and Rough Surfaces; Explosive Precursors in Liquids and Gels |
| Other Chemical Targets |
| Strong Acids in Liquids or Residues on Surfaces. |
| Sample Introduction |
| Solid; Liquid |
| Start Up Time (From Cold Start To Sample Ready) |
| Immediate |
| Response Time (Sample Application To Output) |
| <5 minutes; < 3 minutes |
| Total Run Time |
| < 3 minutes |
| Training Required |
| <1 hour training |
| Training Available |
| Yes |
| Manuals Available |
| Yes |
| Reachback Service |
| No |