ML series (includes the 9000, 9400, and 9700 series)

Polarized light microscope provides identification of anisotropic materials based on their interaction with polarized light. The ML series includes 6 polarizing microscopes that vary based on their illumination, eyepiece and accessories. It is their low-cost, basic capability series.

Notify me on updates of this product 

Availability: Commercially Available

info@meijitechno.com
+1 800 832 0060
5895 Rue Ferrari
San Jose, CA 95138
USA
www.meijitechno.com
Manufacturer
Meiji Techno Co.
Product Name
ML series (includes the 9000, 9400, and 9700 series)
Detection Category
Chemical; Biological; Explosives;
Detection Principle
Microscopy;
Detection Method
Polarized Light Microscopy (PLM);
Application
Laboratory Analysis;
Equipment Type
Instrument
Product Synopsis
Polarized light microscope provides identification of anisotropic materials based on their interaction with polarized light. The ML series includes 6 polarizing microscopes that vary based on their illumination, eyepiece and accessories. It is their low-cost, basic capability series.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
27 cm x 20 cm x 48 cm (LxWxH)
Weight
<30 lbs.; 8.7 kg
Power Requirements
AC/DC Line Power; 115V transformer included
Noise Produced
None
Transportability
Benchtop/Fixed
Ruggedness
None; Fragile
Operating Conditions
Laboratory
Consumables
<$1,000/year; Glass slides, coverslips
Solvents/Reagents
As needed for microchemical reactions and recrystallizations
Calibration Schedule
Before use
Suggested Routine Maintenance
Bulb replacement and lens/filter cleaning as needed.
Available Accessories
Mechanical stage, compensators/filters, camera control units
Data Analysis Support Equipment
None
Communications Interface
None
Expected Operational Life
Decades
Maintenance Cost
$100/yr.
Tested For Explosives
All
Tested For Narcotics
All
Other Chemical Targets
General chemicals, geologic crystalline materials, fibers
Tested For Biological Agents
All
Other Biological Targets
All
Sample Introduction
Solid; Liquid
Sensitivity/Detection Limits
µg; up to 1000x magnification
Start Up Time (From Cold Start To Sample Ready)
<10 seconds
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
<10 min
Software Control
None
Other Operational Parameters
Diascopic, episcopic, orthoscopic and conoscopic observations available
Training Required
>1 week training
Training Available
PLM training available
Manuals Available
Yes
ITAR/EAR Export Regulations
No
IATA Shipping Restrictions
No
Approved Vendors
Meiji Techno Americas
Data File Type Format
None
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: