RAID M100

The RAID M100 is a robust, hand held, multirole IMS Chemical Agent Detector that can identify Chemical Warfare Agents (CWA) and Toxic Industrial Chemicals (TIC) at the lowest levels.

Notify me on updates of this product 

Availability: Commercially Available

Frank Thibodeau
Vice President of Business Development
frank.thibodeau@brukerdetection.us
+1 978 663 3660
40 Manning Road
Billerica, MA 01821
USA
Bruker Daltonics, Inc.
www.bruker.com
Manufacturer
Bruker Corporation
Product Name
RAID M100
Detection Category
Chemical; Explosives;
Detection Principle
Spectrometry;
Detection Method
Ion Mobility Spectrometry;
Application
Emergency Response; Gas Analysis; Screening; Trace Analysis;
Equipment Type
Instrument
Product Synopsis
The RAID M100 is a robust, hand held, multirole IMS Chemical Agent Detector that can identify Chemical Warfare Agents (CWA) and Toxic Industrial Chemicals (TIC) at the lowest levels.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
tooltip-iconAssociated Scoring Levels4 –TRL 9, immediately available
3 – TRL 9 1-2 months delivery after order
2 – TRL 7-8
1 – <TRL 7
Dimensions
15.7 x 4.5 x 6.5 in (40 x 11.4 x 16.5 cm)
Weight
<30 lbs.; 7.5 lbs with batteries (3.4 kg)
tooltip-iconAssociated Scoring Levels4 – <1 lb
3 – <5 Lbs.
2 – <30 Lbs.
1 – >30 Lbs.
Power Requirements
Lithium Battery; Rechargeable
tooltip-iconAssociated Scoring Levels4 – None
3 – Battery or Line Power
2 – Standard Line Power
1 – Non-Standard Line Power
Transportability
Handheld
tooltip-iconAssociated Scoring Levels4 – Handheld
3 – Person-Portable
2 – Mounted
1 – Benchtop/Fixed
Ruggedness
Waterproof/Resistant; Extreme Temperatures/Humidity
Operating Conditions
–30 to 50°C (-22 to 122°F)
Consumables
<$1,000/year; Dust, purge, and drying filters, dopant. Filters are rated for 500 operating hours
tooltip-iconAssociated Scoring Levels4 – No consumables or routine maintenance
3 – Minor consumables (< $1,000/year) and user maintenance
2 – Major consumables (> $1,000/year) and annual vendor provided maintenance
1 – Frequent Service/Manufacturer maintenance required
Suggested Routine Maintenance
Filter and dopant replacement every 500 hours
Data Analysis Support Equipment
Accessories include: Vehicle mounting, remote control, software monitoring, XIMS NT software, filters, dopant, rechargeable spare batteries, com unit, surface sampler, and RS-232 to USB converter
Communications Interface
Interface for connecting to computer networks.
Expected Operational Life
1 to 2 years
Shelf Life
<5 years; 1 to 2 years
Unit Cost
$17,000.00
tooltip-iconAssociated Scoring Levels4 - <$500
3 – <$10,000 per unit
2 – <$50,000 per unit
1 – >$50,000 per unit
Maintenance Cost
$600 to $1,500 per year in consumable costs.
Tested For Chemical Agents
GB, VX, GA, GD, GF, AC, CG, HD, L, HN, CL2
Tested For ITF-25 TIC/TIMs
Chlorine, HCN, HCl, SO2, arsine
Tested For Explosives
No
Tested For Narcotics
No
Other Chemical Targets
Riot control agents, toluene 2,4-diisocyanate, toluene 2,6-diisocyanate
Adaptability
Yes, with optional RAID-NT control software
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm; ppb
tooltip-iconAssociated Scoring Levels4 – Detects trace (<µg/ppm)
3 – Detects less than 1% in mixture
2 – Detects < ~10% in mixture
1 – Detects at > 10%
Known Interferents/Inhibitors
Typical interferents for IMS detector, including JP-8, gasoline, floor wax, window cleaner
tooltip-iconAssociated Scoring Levels4 – <1% False Positive and Negative Rate, no known Interferences
3 – <5% False Positive and Negative Rate, <5 known Interferences
2 – <10% False Positive and Negative Rate, <5 known Interferences
1 – >10% False Positive and Negative Rate, >5 known Interferences
Start Up Time (From Cold Start To Sample Ready)
1 to 5 minutes
Response Time (Sample Application To Output)
<1 minute
tooltip-iconAssociated Scoring Levels4 – Continuous/<60 Seconds
3 – <5 minute
2 – <15 minute
1 – > 15 minutes
Alarm Capability
Audible and visual
Software Control
XIMS-NT software
Other Operational Parameters
Automatic purge mode to prevent saturation and achieve fast recovery time.
Training Required
<1 day training
Training Available
Self-training. Instructor training available for additional cost.
Manuals Available
Operator’s manual
Warranties
1 year factory warranty. Extended warranties at 5% per year up to 5 years.
ITAR/EAR Export Regulations
Yes; U.S. Nuclear Regulatory Agency regulations due to 63Ni source. Source activity is 100 MBq (2.7 mCi).
IATA Shipping Restrictions
Yes; U.S. Nuclear Regulatory Agency regulations due to 63Ni source. Source activity is 100 MBq (2.7 mCi).
tooltip-iconAssociated Scoring Levels4 – Unregulated
3 – Ground and Cargo Air Only
2 – Ground Only
1 – IATA/DOT Certification Required/Hazardous Materials