S1 Titan LE/SP

The S1 TITAN a tube-based handheld XRF analyzer. Features include a touch-screen color display, 50 kV X-ray tube, SMART grade timing, sharp beam optimized X-ray geometry, and a housing that is sealed against humid and dusty environments. The S1 TITAN series is available in two configurations LE and SP. The LE has a SDD detector (Model 500, 600 and 800) and the SP is a SiPIN detector (Model 200, 300).

Notify me on updates of this product 

Availability: Commercially available

Frank Thibodeau
Vice President of Business Development
frank.thibodeau@brukerdetection.us
+1 978 663 3660
40 Manning Road
Billerica, MA 01821
USA
Bruker AXS, Inc.
www.bruker.com
Manufacturer
Bruker Corporation
Product Name
S1 Titan LE/SP
Detection Category
Chemical; Explosives
Detection Principle
Elemental Analysis;
Detection Method
X-ray Fluorescence ;
Application
Emergency Response; Screening; Bulk Analysis;
Product Model Number
Models 200, 300, 500, 600, 800
Equipment Type
Instrument
Product Synopsis
The S1 TITAN a tube-based handheld XRF analyzer. Features include a touch-screen color display, 50 kV X-ray tube, SMART grade timing, sharp beam optimized X-ray geometry, and a housing that is sealed against humid and dusty environments. The S1 TITAN series is available in two configurations LE and SP. The LE has a SDD detector (Model 500, 600 and 800) and the SP is a SiPIN detector (Model 200, 300).
Availability
Commercially available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
10 x 11 x 3.7 in (254 x 280 x 94 mm)
Weight
<5 Lbs.; 3.2 Lbs. (1.5 kg)
Power Requirements
Lithium Battery; AC/DC Line Power; 7.2V Li-Ion rechargeable, 9V AC adaptor
Noise Produced
Negligible
Transportability
Handheld
Operating Conditions
–10 to 50°C (14 to 122°F)
Consumables
None
Available Accessories
Battery Charger
Communications Interface
USB
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$50,000.00
Other Chemical Targets
Elemental analysis
Adaptability
No; cannot detect or add new targets
Sample Introduction
Solid
Start Up Time (From Cold Start To Sample Ready)
15 minutes
Response Time (Sample Application To Output)
<5 minutes; 2 minutes
Total Run Time
< 20 minutes
Alarm Capability
No
Software Control
On-board
Other Operational Parameters
Elemental Range: LE: Mg-U; SP: Ca-U; Max Sample Temperature: LE:150°C; SP: 500°C; Spot Size: LE: 3,5, or 8mm; SP: 5mm
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: