DMC Series

The DMC 2000GN uses a unique licensed neutron detection technology based on a large single diode. The DMC 2000S features flat energy response to X-rays and gamma field from 50keV to 6Mev and linear response to dose rate fields from natural background up to more than 10 Sv/h. The DMC 3000 Personal Electronic Dosimeter has a rugged, high impact polycarbonate-ABS case. They are designed to be worn on the body and keep a live record of both dose and dose rate. It operates with 2 push buttons.

Notify me on updates of this product 

Availability: Commercially available

Carol McGowan
Homeland Security and Defense Sales Manager
cmcgowan@mirion.com
+1 770 329 3228
5000 Highlands Parkway, Suite 150
Smyrna, GA 30082
USA
+1 770 432 2744
www.mirion.com
Manufacturer
Mirion Technologies
Product Name
DMC Series
Detection Category
Radiological/Nuclear;
Detection Principle
Geiger-Muller Detectors;
Detection Method
Geiger-Muller Detectors;
Application
Dosimeters;
Product Model Number
2000GN, 2000S, 3000
Equipment Type
Instrument
Product Synopsis
The DMC 2000GN uses a unique licensed neutron detection technology based on a large single diode. The DMC 2000S features flat energy response to X-rays and gamma field from 50keV to 6Mev and linear response to dose rate fields from natural background up to more than 10 Sv/h. The DMC 3000 Personal Electronic Dosimeter has a rugged, high impact polycarbonate-ABS case. They are designed to be worn on the body and keep a live record of both dose and dose rate. It operates with 2 push buttons.
Availability
Commercially available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
3.4 x 1.9 x 0.85 in (8.6 x 4.8 x 2.1 cm) (2000GN) 3.3 x 1.9 x 0.7 in (8.4 x 4.8 x 1.75 cm) (2000S) 3.4 x 2.2 x 0.85 in (8.6 x 5.6 x 2.1 cm) (3000)
Weight
<1 lb.; 2.8 to 3.1 oz (79 to 87 g)
Power Requirements
Lithium Battery; LiMnO2 CR2450 battery, 1 year battery life with 8 hour per day usage.
Transportability
Pocket Size
Ruggedness
Waterproof/Resistant; Vibration/Shock
Operating Conditions
-10 to 50°C (14 to 122°F); < 90%RH
Consumables
None
Expected Operational Life
Indefinite
Shelf Life
>5 years
Radiological Targets
Gamma, X-ray
Adaptability
No
Sample Introduction
Radioactive Particle
Sensitivity/Detection Limits
µSv; Sv; 1 uSv to 10 Sv
False Positive Rates
< 10 %
False Negative Rates
< 10 %
Start Up Time (From Cold Start To Sample Ready)
Seconds
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Continuous
Alarm Capability
Audible and Visual
Other Operational Parameters
X and gamma energy range: 50 keV to 6 MeV
Training Required
<1 hour training
Training Available
Yes
Manuals Available
Yes
Reachback Service
No
IATA Shipping Restrictions
Yes; Lithium ion battery
Approved Vendors
Arrow-Tech, Inc.
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: