Handheld LIBS Analyzer for Metal Alloys
The handheld LIBS (laser induced breakdown spectroscopy) analyzer, mPulse, is optimized for the rapid sorting of metal alloys. It identifies a wide variety of metal alloys at the press of the trigger and measures elements, light and heavy in only 1 second. Its point-and-shoot operation allows for the testing of large or small samples such as shavings, turnings, granules, cables etc.
Availability: DISCONTINUED
| Manufacturer |
| Oxford Instruments |
| Product Name |
| Handheld LIBS Analyzer for Metal Alloys |
| Detection Category |
| Chemical |
| Detection Principle |
| Elemental Analysis; |
| Detection Method |
| Laser Induced Breakdown Spectroscopy; |
| Application |
| Screening; Bulk Analysis; Forensics; |
| Product Model Number |
| mPulse; mPulse+ |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The handheld LIBS (laser induced breakdown spectroscopy) analyzer, mPulse, is optimized for the rapid sorting of metal alloys. It identifies a wide variety of metal alloys at the press of the trigger and measures elements, light and heavy in only 1 second. Its point-and-shoot operation allows for the testing of large or small samples such as shavings, turnings, granules, cables etc. |
| Availability |
| DISCONTINUED |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 13 x 13 x 5 in (330 x 340 x 130 mm) |
| Weight |
| <5 Lbs.; 4 Lbs. (1.8 kg) |
| Power Requirements |
| Lithium Battery |
| Noise Produced |
| Neglibible |
| Transportability |
| Handheld |
| Ruggedness |
| None; Optics are protected by a sapphire window to prevent contamination and damage |
| Operating Conditions |
| Extreme environments |
| Consumables |
| <$1,000/year; Lens cleaner; Batteries |
| Solvents/Reagents |
| None |
| Suggested Routine Maintenance |
| Minimal |
| Communications Interface |
| USB |
| Shelf Life |
| >5 years |
| Unit Cost |
| $25,000 - $30,000 |
| Tested For Chemical Agents |
| No |
| Tested For ITF-25 TIC/TIMs |
| No |
| Tested For Explosives |
| No |
| Tested For Narcotics |
| No |
| Other Chemical Targets |
| Elements |
| Sample Introduction |
| Solid |
| Sensitivity/Detection Limits |
| % |
| Start Up Time (From Cold Start To Sample Ready) |
| 2 minutes |
| Response Time (Sample Application To Output) |
| Continuous (<30 seconds); 1 second |
| Total Run Time |
| < 5 minutes |
| Alarm Capability |
| No |
| Software Control |
| On-board, PC |
| Other Operational Parameters |
| None |
| Training Required |
| <1 day training |
| Training Available |
| Operator’s Manual |