KeDetect CW SICAS
The KeDetect CW SICAS (Ship Installed Chemical Alarm System) is a ship-powered CWA biosensor that uses immobilized enzymes as the sensing technology. The vendor claims the SICAS can detect all known and unknown nerve agents, including Novichok and FTA variants. Limits of detection are sub-miosis level. Also detects attack concentrations of hydrogen cyanide (HCN). The vendor literature does not provide details of the sensing technology used in this product.
Availability: DISCONTINUED
Robert Chandler
Business Development Manager
44 1159 005600
Glaisdale Drive East
Nottingham, UK
Nottinghamshire
9am - 5pm, Mon - Fri
|
Maggie McBrearty
Sales Admin
44 1159 005600
Glaisdale Drive East
Nottingham, UK
Nottinghamshire
9am - 5pm, Mon - Fri
|
www.ketechdefence.com
Manufacturer |
| KeTech Systems Ltd |
Product Name |
| KeDetect CW SICAS |
Detection Category |
| Chemical; |
Detection Principle |
| Sensors; |
Detection Method |
| Enzymatic; |
Application |
| Emergency Response; Screening; Bulk Analysis; Trace Analysis; |
Product Model Number |
| SICAS |
Equipment Type |
| Instrument |
Product Synopsis |
| The KeDetect CW SICAS (Ship Installed Chemical Alarm System) is a ship-powered CWA biosensor that uses immobilized enzymes as the sensing technology. The vendor claims the SICAS can detect all known and unknown nerve agents, including Novichok and FTA variants. Limits of detection are sub-miosis level. Also detects attack concentrations of hydrogen cyanide (HCN). The vendor literature does not provide details of the sensing technology used in this product. |
Availability |
| DISCONTINUED |
Technology Readiness Level (TRL) |
| 9 |
Market Entry Date |
| 1995 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| Installation specific |
Weight |
| <30 lbs.; 8Kg |
Power Requirements |
| Lithium Battery; Ships Battery |
Noise Produced |
| 95Db |
Transportability |
| Person-Portable |
Ruggedness |
| Waterproof/Resistant; Dust; Vibration/Shock; MIL-STD, IP rated |
Operating Conditions |
| 0 to 50°C (32 to 122°F) |
Consumables |
| <$1,000/year; Chemical Reagent Module, Enzyme Pad |
Solvents/Reagents |
| Liquid; Solid |
Calibration Schedule |
| None |
Suggested Routine Maintenance |
| Keep inlet free of obstructions |
Available Accessories |
| Captains Repeater Panel, Remote Status Panel, TBU, Field Test Kit |
Expected Operational Life |
| 10 years |
Shelf Life |
| >5 years |
Maintenance Cost |
| Consumable change every 12 hours of active operation |
Tested For Chemical Agents |
| All Known and Not specified Nerve Agents |
Tested For ITF-25 TIC/TIMs |
| Yes |
Tested For Explosives |
| No |
Tested For Narcotics |
| No |
Other Chemical Targets |
| Hydrogen Peroxide |
Tested For Biological Agents |
| No |
Other Biological Targets |
| No |
Radiological Targets |
| No |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| ppb |
False Positive Rates |
| 0 |
Start Up Time (From Cold Start To Sample Ready) |
| 5 minutes |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds); < 1 second |
Alarm Capability |
| Audio; Visual |
Software Control |
| No |
Training Required |
| <1 day training |
Training Available |
| Yes |
Manuals Available |
| Yes |
Warranties |
| Yes |