A Series
The A series are handheld instruments used to identify and localize isotopes in the field. The A100 is lower efficiency with reduced CZT volume. The A401 is also a neutron detector with 5.1 cps/nv sensitivity.
Availability: Commercially Available
| Manufacturer |
| H3D, Inc. |
| Product Name |
| A Series |
| Detection Category |
| Radiological/Nuclear; |
| Detection Principle |
| Semiconductors; |
| Detection Method |
| Geiger-Muller Detectors; |
| Application |
| Identifiers;Personal Radiation Detectors; |
| Product Model Number |
| A100, A400, A401 |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The A series are handheld instruments used to identify and localize isotopes in the field. The A100 is lower efficiency with reduced CZT volume. The A401 is also a neutron detector with 5.1 cps/nv sensitivity. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Supporting Documentation |
| Docs: A series.pdf; |
| Dimensions |
| 5.5 x 11 x 4 in (14 x 28 x 10 cm) |
| Weight |
| <5 lbs.; 2.3 kg |
| Power Requirements |
| AC/DC Line Power; Lithium Battery; 100 to 240 V, 47-63 Hz, battery (9 hours) |
| Transportability |
| Handheld |
| Ruggedness |
| Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; IP67 |
| Operating Conditions |
| -20 to 50°C (-4 to 122°F) |
| Consumables |
| None |
| Calibration Schedule |
| Annually by vendor |
| Suggested Routine Maintenance |
| None |
| Available Accessories |
| IM2100Pelican™ Storage Case |
| Data Analysis Support Equipment |
| 3.5” embedded screen with 3-button control, Internet-browser based interface |
| Communications Interface |
| Wi-Fi, bluetooth |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| >5 years |
| Unit Cost |
| $50,000.00 |
| Maintenance Cost |
| None |
| Radiological Targets |
| Gamma |
| Number of Library Entries |
| 3,573 isotope ENDF library |
| Adaptability |
| No; cannot detect or add new targets |
| Sample Introduction |
| Radioactive Particle |
| Sensitivity/Detection Limits |
| cps; mR; µR; mrem/hr; µR/hr |
| Start Up Time (From Cold Start To Sample Ready) |
| < 2 minutes |
| Response Time (Sample Application To Output) |
| <5 minutes; 20 to 120 seconds |
| Total Run Time |
| 20 to 120 seconds |
| Alarm Capability |
| Audible and visual |
| Software Control |
| On-board |
| Other Operational Parameters |
| Energy Range: 50 keVto 3 MeV (spectroscopy), 100 keVto 3 MeV (directionality). 32 GB internal data storage. GPS embedded. |
| Training Required |
| <1 day training |
| Training Available |
| Yes |
| Manuals Available |
| Yes |
| Warranties |
| 2 year |
| ITAR/EAR Export Regulations |
| Yes; Subject to U.S. Export Control (EAR) |
| Data File Type Format |
| ANSI N42.42 xml |