mrem Electronic Personal Dosimeters
The Model 23 mrem Electronic Personal Dosimeter is a compact and lightweight pen-type personal dosimeter. Designed for the measurement and general monitoring of gamma and X-ray radiation in medical and laboratory environments, as well as any controlled or restricted area where personal radiation monitoring is required or desired.
Availability: Commercially Available
Manufacturer |
| Ludlum Measurements, Inc. |
Product Name |
| mrem Electronic Personal Dosimeters |
Detection Category |
| Radiological/Nuclear; |
Detection Principle |
| Semiconductors; |
Detection Method |
| Semiconductors; |
Application |
| Personal Radiation Detectors;Dosimeters; |
Product Model Number |
| Model 23, Model 23-1 |
Equipment Type |
| Instrument |
Product Synopsis |
| The Model 23 mrem Electronic Personal Dosimeter is a compact and lightweight pen-type personal dosimeter. Designed for the measurement and general monitoring of gamma and X-ray radiation in medical and laboratory environments, as well as any controlled or restricted area where personal radiation monitoring is required or desired. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Supporting Documentation |
| Docs: Ludlum-Model 23 personal dosimeter.pdf; |
Dimensions |
| 4.3 x 1.8 x 0.5 in (110 x 30 x 12 mm)without clip |
Weight |
| <1 lb.; 2 oz (55.9 g) |
Power Requirements |
| Lithium Battery; Li-ion battery (one month at eight hours per day in non-alarm status) |
Noise Produced |
| 60 dB; alarm can be muted |
Transportability |
| Pocket Size |
Operating Conditions |
| -10 to 40 °C (14 to 104 °F); < 90% RH (non-condensing) |
Consumables |
| None |
Suggested Routine Maintenance |
| None |
Available Accessories |
| Reader/software kit |
Data Analysis Support Equipment |
| Reader/software kit |
Expected Operational Life |
| 10 years |
Shelf Life |
| >5 years |
Unit Cost |
| $391.00 |
Maintenance Cost |
| None |
Radiological Targets |
| Gamma, X-ray |
Sample Introduction |
| Radioactive Particle |
Sensitivity/Detection Limits |
| µSv; cpm; ~ 20 cpm /µR/hr |
Start Up Time (From Cold Start To Sample Ready) |
| Seconds |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
Total Run Time |
| Continuous |
Alarm Capability |
| Audible |
Software Control |
| PC |
Other Operational Parameters |
| Energy range: 35 keV to 3 MeV. |
Training Required |
| <1 day training |
Manuals Available |
| Yes |
Warranties |
| 1 year |
ITAR/EAR Export Regulations |
| No |
IATA Shipping Restrictions |
| No |
Approved Vendors |
| Laco |