MBD-2
The MBD-2 dosimeter is a real-time, self-indicating device that requires no user intervention for operation. The MBD-2 dosimeter is based upon Mirion Technologies’ patented Direct Ion Storage (DIS) technology. It is ergonomic, and designed to be worn comfortably on the wrist, or clipped to a garment.
_x00F_
The MBD-2 is lightweight and low profile in size. Its edges are rounded to accommodate clothing and gear. The device closely resembles a wristwatch and therefore is natural to observe when reading the display.
Availability: Commercially Available
| Manufacturer |
| Mirion Technologies |
| Product Name |
| MBD-2 |
| Detection Category |
| Radiological/Nuclear; |
| Detection Principle |
| Scintillation Detectors; |
| Detection Method |
| Scintillation Detectors; |
| Application |
| Personal Radiation Detectors;Dosimeters; |
| Product Model Number |
| MBD-2 |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The MBD-2 dosimeter is a real-time, self-indicating device that requires no user intervention for operation. The MBD-2 dosimeter is based upon Mirion Technologies’ patented Direct Ion Storage (DIS) technology. It is ergonomic, and designed to be worn comfortably on the wrist, or clipped to a garment.
_x00F_
The MBD-2 is lightweight and low profile in size. Its edges are rounded to accommodate clothing and gear. The device closely resembles a wristwatch and therefore is natural to observe when reading the display. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Supporting Documentation |
| Docs: mbd-2-spec-sheet.pdf; |
| Dimensions |
| 2.08 x 2.2 x 0.94 in (5.2 x 5.6 x 2.4 cm) |
| Weight |
| <1 lb.; 2 oz (57 g) with batteries |
| Power Requirements |
| Lithium Battery |
| Transportability |
| Pocket Size |
| Ruggedness |
| None |
| Operating Conditions |
| Environmental and EML compliant |
| Consumables |
| None |
| Suggested Routine Maintenance |
| None |
| Available Accessories |
| Reader software, data collector |
| Data Analysis Support Equipment |
| PC, software |
| Communications Interface |
| NFC or BLE communication |
| Shelf Life |
| >5 years |
| Maintenance Cost |
| None |
| Radiological Targets |
| Gamma, neutron |
| Sample Introduction |
| Radioactive Particle |
| Sensitivity/Detection Limits |
| mR; 1 mrem to 2000 rem. |
| Start Up Time (From Cold Start To Sample Ready) |
| Seconds |
| Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
| Total Run Time |
| Continuous |
| Alarm Capability |
| Audible and visual |
| Software Control |
| PC |
| Other Operational Parameters |
| Internal histogram, pulsed x-ray measurements to 65 nsec pulses. |
| Training Required |
| <1 hour training |
| Training Available |
| Yes |
| Manuals Available |
| Yes |
| Warranties |
| 1 year |
| IATA Shipping Restrictions |
| Yes; Li-ion batteries |