ASSURx

The ASSURx is a handheld Raman analyzer with a gun-style, point and shoot design. It weighs about 5 lbs, uses a daily polystyrene check standard, and has a spectral range of 250 to 2350 cm-1.

Notify me on updates of this product 

Availability: DISCONTINUED

Amy Bauer, Ph.D.
amy.bauer@tsi.com
+1 800 874 2811
500 Cardigan Road
Shoreview, MN 55126
USA
www.tsi.com
Manufacturer
TSI, Inc.
Product Name
ASSURx
Detection Category
Chemical; Explosives
Detection Principle
Molecular Spectroscopy;
Detection Method
Raman Spectroscopy;
Application
Bulk Analysis;Emergency Response;Screening;
Equipment Type
Instrument
Product Synopsis
The ASSURx is a handheld Raman analyzer with a gun-style, point and shoot design. It weighs about 5 lbs, uses a daily polystyrene check standard, and has a spectral range of 250 to 2350 cm-1.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Supporting Documentation
Docs: TSI - ASSURx.pdf;
Dimensions
9.21 x 4 x 8.77 in (23.4 x 10 x 22.3 cm)
Weight
<30 lbs.; 5.25 lbs (2.4 kg)
Power Requirements
Lithium Battery; AC/DC Line Power; Li-ion battery (> 3 hours); DC Wall Adapter, 100/220 VAC 50/60 Hz
Transportability
Handheld
Ruggedness
None
Operating Conditions
0 to 40°C (32 to 104°F)
Consumables
<$1,000/year; sample vials
Calibration Schedule
Polystyrene PQ check standard daily
Available Accessories
Battery charging stand, tablet holder, vial holder, 7mm focusing lens for thicker glass/packaging, polystyrene PQ check standard, acetaminophen, acetylsalicyclic acid check samples. Optional: immersion probe
Data Analysis Support Equipment
PC, software
Communications Interface
USB, ethernet
Expected Operational Life
10,000 hours (laser source)/ 5 years
Shelf Life
>5 years
Unit Cost
$32,500.00
Tested For Chemical Agents
Yes
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
Yes
Tested For Narcotics
Yes; fentanyl, carfentanil, sufentanil, alfentanil, remifentanil, heroin, ketamine, lorazepam, 3-quinuclidinyl benzilate, U-47700
Adaptability
Yes; user can add new targets in the field
Sample Introduction
Liquid;Solid;
Sensitivity/Detection Limits
%
Known Interferents/Inhibitors
Fluorescence
Start Up Time (From Cold Start To Sample Ready)
< 5 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds); 5 to 20 seconds
Total Run Time
Varies by sample
Software Control
On-board, PC
Other Operational Parameters
Laser wavelength: 785 nm, line width , 0.15 nm. Spectral range: 250 to 2350 cm-1
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Warranties
1 year parts and labor. Extended warranties also available.
IATA Shipping Restrictions
Yes; Lithium ion battery
Data File Type Format
SPC, TXT, EPT, PDF
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: