BioCapture 650

Developed under ICX Technologies, the BioCapture 650 is a handheld air sampling device designed to detect biological warfare agents. The device can be used while wearing Level A suits, and uses a large single button for operation. It contains a rotating impactor, fluid chamber, fluid lines and sample vial pre-assembled in one disposable cartridge. When the operation is complete, replace the cartridge and move on to the next operation. The device is 100% decontamination abled.

Notify me on updates of this product 

Availability: DISCONTINUED

Ezra Merrill
Director of Sales and Marketing
+1 505 314 8100
1001 Menaul Boulevard NE, Suite A
Albuquerque, NM 87107
USA
www.thermoscientific.com
Manufacturer
Thermo Fisher Scientific, Inc.
Product Name
BioCapture 650
Detection Category
Biological
Detection Principle
Sample Collection;
Detection Method
Sample Collection
Application
Sample Collection; Emergency Response; Detection;
Product Model Number
19-120-3873
Equipment Type
Sample Collection
Product Synopsis
Developed under ICX Technologies, the BioCapture 650 is a handheld air sampling device designed to detect biological warfare agents. The device can be used while wearing Level A suits, and uses a large single button for operation. It contains a rotating impactor, fluid chamber, fluid lines and sample vial pre-assembled in one disposable cartridge. When the operation is complete, replace the cartridge and move on to the next operation. The device is 100% decontamination abled.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
Market Entry Date
2011
User Feedback Sources
Indifferent/No user feedback
Dimensions
5.25 x 6 x 14.5 in (13.3 x 15.4 x 36.8 cm)
Weight
<30 Lbs.; 7.5 Lbs. (3.4 kg)
Power Requirements
Lithium Battery
Transportability
Handheld
Ruggedness
Dust; Waterproof/Resistant
Operating Conditions
2 to 43°C (35 to 110°F) 5 to 95% RH non-condensing
Consumables
>$1,000/year; Cartridges
Solvents/Reagents
None
Data Analysis Support Equipment
None
Expected Operational Life
2 hour battery life
Unit Cost
$14,867.00
Tested For Biological Agents
Anthrax, plague, smallpox, ricin
Other Biological Targets
Yes
Sample Introduction
Vapor/Gas;
Response Time (Sample Application To Output)
<5 minutes
Total Run Time
5, 15, 30 and 60 minute sampling time
Other Operational Parameters
0.5 to 10 micron
Training Required
<1 day training
Manuals Available
Yes
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: