MX908
MX908™ leverages high-pressure mass spectrometry™ (HPMS) to deliver enhanced sensitivity and threat category coverage. MX908 can detect and identify trace quantities (low - mid ppb) of priority threats amongst a myriad of interferents. It is capable of identifying a broad range of targets in solid, liquid, gas/vapor, or aerosol form.
Availability: Commercially Available
Manufacturer |
| 908 Devices, Inc. |
Product Name |
| MX908 |
Detection Category |
| Chemical; Explosives; |
Detection Principle |
| Spectrometry; |
Detection Method |
| Ion Trap Mass Spectrometry;High-Pressure Mass Spectrometry; |
Application |
| Emergency Response;Forensics;Screening;Bulk Analysis;Trace Analysis;Decontamination;Gas Analysis;Mail Screening; |
Product Model Number |
| MX908 |
Equipment Type |
| Instrument |
Product Synopsis |
| MX908™ leverages high-pressure mass spectrometry™ (HPMS) to deliver enhanced sensitivity and threat category coverage. MX908 can detect and identify trace quantities (low - mid ppb) of priority threats amongst a myriad of interferents. It is capable of identifying a broad range of targets in solid, liquid, gas/vapor, or aerosol form. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
Market Entry Date |
| 2017 |
User Feedback Sources |
| Positive user feedback, Market leader; MRIGlobal hands-on experience, DOD, Extensive 3rd party and field testing |
Supporting Documentation |
| Docs: 908 - MX908.pdf; |
Dimensions |
| 11.8 x 8.5 x 4.8 in (29.8 x 21.6 x 12.2 cm) |
Weight |
| < 9.5 Lbs. (4.3 kg) |
Power Requirements |
| Lithium Battery; Replaceable, hot swappable batteries
(2 spare batteries included) > 2-3 hour continuous use depending on mode |
Noise Produced |
| Negligible, low humming in vapor mode |
Transportability |
| Handheld |
Ruggedness |
| Waterproof/Resistant; Dust; Vibration/Shock; IP54. Rubber boot.Shock and vibration testing. |
Operating Conditions |
| 0 to 40°C (32 to 110°F) |
Consumables |
| <$1,000/year; Trace analysis requires trace sampling swabs and microsamplers for bulk samples only. |
Calibration Schedule |
| None required |
Suggested Routine Maintenance |
| Minimal; designed for non-technical users |
Available Accessories |
| Sampling probe, Aero module, MX908 Beacon for area monitoring |
Data Analysis Support Equipment |
| N/A for on-device analysis
PC for advanced spectral viewing |
Communications Interface |
| USB, Serial Port |
Expected Operational Life |
| 5-7 years |
Shelf Life |
| >5 years; Indefinite (Li-ion battery pack has a lifetime of 3 years) |
Unit Cost |
| $65,000.00 |
Maintenance Cost |
| No scheduled maintenance. |
Tested For Chemical Agents |
| A-series (Novichoks), HD, GA, GB, GD, GF, VX plus additional V-series agents. Contact manufacturer for latest target list and test reports. |
Tested For ITF-25 TIC/TIMs |
| DEEP, DIMP, TEP, GD acid, TMP, dimethyl sulfate, carbon disulfide, allyl amine, allyl alcohol. Contact manufacturer for latest target list and test reports. |
Tested For Explosives |
| ETN, HMTD, HMX, MEKP, PETN, RDX, TNT, TATP, nitrobenzene and more. Contact manufacturer for latest target list and test reports. |
Tested For Narcotics |
| Fentanyl, fentanyl analogs, U-47700, hydrocodone, oxycodone, heroin, cocaine, amphetamines, ephedrine, MDMA, methadone, methamphetamine, carfentanil, sufentanil, alfentanil, remifentanil, ketamine and more. Contact manufacturer for latest target list and test reports. |
Other Chemical Targets |
| Solid organic materials |
Number of Library Entries |
| > 200 unique targets, classification of 2,000+ fentanyl analogs |
Adaptability |
| Yes; User can add new targets in the field |
Sample Introduction |
| Vapor/Gas;Solid;Liquid;Particle; |
Sensitivity/Detection Limits |
| ppb; ng; µg |
Known Interferents/Inhibitors |
| None |
Start Up Time (From Cold Start To Sample Ready) |
| < 5 minutes |
Response Time (Sample Application To Output) |
| <1 minute; Seconds (vapor) to 60 seconds (trace) |
Total Run Time |
| < 5 minutes |
Alarm Capability |
| Audible and visual |
Software Control |
| On-board, Remote control possible |
Other Operational Parameters |
| User collects solid samples with thermal desorption swabs, Mass Range 50 to 500 Da |
Training Required |
| <1 day training |
Training Available |
| Yes. In person and virtual |
Manuals Available |
| Yes |
Reachback Service |
| Yes |
Warranties |
| 1-5 year warranties available |
ITAR/EAR Export Regulations |
| This device is subject to export controls including those of the Export Administration Regulations of the U.S. Department of Commerce, which may restrict or require licenses for the export of product from the United States and their re-export to and from other countries. |
IATA Shipping Restrictions |
| Yes; Lithium ion battery restrictions |
Data File Type Format |
| PDF, JPEG, CSV, Reachback (OXP) |