FROG-5000™
The FROG-5000™ delivers lab quality results in the field. In less than 10 minutes, the operator can detect volatile organic compounds in air, water, and soil. The FROG-5000™ portable GC will detect chemicals as volatile as vinyl chloride in addition to semi-volatile organic compounds such as naphthalene. The FROG-5000™ can detect VOCs at sub-ppb levels or at high ppm levels depending on its configuration.
Availability: Commercially Available
Manufacturer |
| Defiant Technologies |
Product Name |
| FROG-5000™ |
Detection Category |
| Chemical |
Detection Principle |
| Sensors;Chromatography; |
Detection Method |
| Photoionization Detection;Gas Chromatography; |
Application |
| Gas Analysis;Water Quality;Emergency Response; |
Equipment Type |
| Instrument |
Product Synopsis |
| The FROG-5000™ delivers lab quality results in the field. In less than 10 minutes, the operator can detect volatile organic compounds in air, water, and soil. The FROG-5000™ portable GC will detect chemicals as volatile as vinyl chloride in addition to semi-volatile organic compounds such as naphthalene. The FROG-5000™ can detect VOCs at sub-ppb levels or at high ppm levels depending on its configuration. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Supporting Documentation |
| Docs: Frog 5000.pdf; |
Dimensions |
| 11 x 7.75 x 12 in (23 x 19.6 x 30 cm) |
Weight |
| <5 lbs.; 4.8 lbs (2.2 kg) |
Power Requirements |
| Lithium Battery; Rechargeable Lithium Ion, 3A Power Supply (9 hours) |
Transportability |
| Handheld |
Ruggedness |
| None |
Consumables |
| <$1,000/year; Purge tube |
Solvents/Reagents |
| Purge gas |
Data Analysis Support Equipment |
| PC, software |
Communications Interface |
| Micro SD card |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Unit Cost |
| $25,200.00 |
Tested For Chemical Agents |
| Not tested; amenable by technology |
Tested For ITF-25 TIC/TIMs |
| Benzene, Toluene, Ethylbenzene, Xylenes (BTEX), Vinyl Chloride, trans-1,2-Dichloroethene, cis-1,2-Dichloroethene, Trichloroethene (TCE), Tetrachloroethene (PCE), (Chlorinated Alkenes), Naphthalene. |
Tested For Explosives |
| Not tested; amenable by technology |
Tested For Narcotics |
| Not tested; amenable by technology |
Other Chemical Targets |
| Not tested; amenable by technology |
Adaptability |
| Yes, user can add new targets to detector with support using PC software |
Sample Introduction |
| Liquid;Vapor/Gas |
Sensitivity/Detection Limits |
| ppt; ppb |
Response Time (Sample Application To Output) |
| <15 minutes; < 10 minutes |
Software Control |
| PC |
Training Required |
| <1 week training |
Training Available |
| Yes |
Manuals Available |
| Yes |
Warranties |
| Yes |
IATA Shipping Restrictions |
| Yes; Lithium ion battery, carrier gas |