700 FTIR
The California Analytical Instruments 700 FTIR Analyzer provides fast, continuous and stable analysis of virtually any gas that has an infrared absorption spectrum. The heated sample cell enables the instrument to accommodate hot samples containing high levels of moisture.
Availability: Commercially Available
Manufacturer |
| ENVEA |
Product Name |
| 700 FTIR |
Detection Category |
| Chemical; Explosives |
Detection Principle |
| Molecular Spectroscopy; |
Detection Method |
| Near Infrared; |
Application |
| Gas Analysis; |
Product Model Number |
| 700 FTIR |
Equipment Type |
| Instrument |
Product Synopsis |
| The California Analytical Instruments 700 FTIR Analyzer provides fast, continuous and stable analysis of virtually any gas that has an infrared absorption spectrum. The heated sample cell enables the instrument to accommodate hot samples containing high levels of moisture. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 10.5 x 19 x 28 in (17 x 48 x 71 cm) |
Weight |
| >50 lbs.; 90 lbs (41 kg) |
Power Requirements |
| AC/DC Line Power; 115 VAC/60Hz or 230 VAC/50Hz |
Transportability |
| Benchtop/Fixed; Small Footprint |
Operating Conditions |
| 5 to 40°C (41 to 104°F), < 90% RH |
Consumables |
| None |
Data Analysis Support Equipment |
| PC, software |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Tested For ITF-25 TIC/TIMs |
| Carbon Dioxide, Carbon Monoxide, Nitric Oxide, Nitrogen Dioxide, Sulfur Dioxide, Nitrous Oxide, Hydrogen Chloride, Ammonia, Methane, Propane, Butane, Ethane, Ethanol, Ethylene, Propylene, Toluene, Acetylene, Chloroform, Dichloroethylene, Ethyl Benzene, Methyl Ethyl Ketone, Formaldehyde, Sulfur Hexafluoride, Phosgene, Vinyl Chloride, R134A |
Adaptability |
| Yes; manufacturer can add new targets to detector |
Sample Introduction |
| Vapor/Gas; |
Sensitivity/Detection Limits |
| ppb; ppm; % |
Start Up Time (From Cold Start To Sample Ready) |
| 20 seconds to 5 minutes |
Response Time (Sample Application To Output) |
| <5 minutes; 20 seconds to 5 minutes |
Total Run Time |
| Continuous |
Software Control |
| Rack-mount PC or laptop-controlled with
OPUS software |
Other Operational Parameters |
| 10.2-meter optical path, Heated sample cell (50°or 191°C), 0.8 wave number (cm–1 ) resolution. No liquid nitrogen required. |
Training Required |
| <1 day training |
Training Available |
| Yes |
Manuals Available |
| Yes |
IATA Shipping Restrictions |
| No |