700 FTIR

The California Analytical Instruments 700 FTIR Analyzer provides fast, continuous and stable analysis of virtually any gas that has an infrared absorption spectrum. The heated sample cell enables the instrument to accommodate hot samples containing high levels of moisture.

Notify me on updates of this product 

Availability: Commercially Available

Darrell Parson
dparson@gasanalyzers.com
+1 800 959 0949 ext. 306
1312 West Grove Avenue
Orange, CA 92865-4134
www.gasanalyzers.com
Manufacturer
ENVEA
Product Name
700 FTIR
Detection Category
Chemical; Explosives
Detection Principle
Molecular Spectroscopy;
Detection Method
Near Infrared;
Application
Gas Analysis;
Product Model Number
700 FTIR
Equipment Type
Instrument
Product Synopsis
The California Analytical Instruments 700 FTIR Analyzer provides fast, continuous and stable analysis of virtually any gas that has an infrared absorption spectrum. The heated sample cell enables the instrument to accommodate hot samples containing high levels of moisture.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
10.5 x 19 x 28 in (17 x 48 x 71 cm)
Weight
>50 lbs.; 90 lbs (41 kg)
Power Requirements
AC/DC Line Power; 115 VAC/60Hz or 230 VAC/50Hz
Transportability
Benchtop/Fixed; Small Footprint
Operating Conditions
5 to 40°C (41 to 104°F), < 90% RH
Consumables
None
Data Analysis Support Equipment
PC, software
Expected Operational Life
Indefinite
Shelf Life
>5 years
Tested For ITF-25 TIC/TIMs
Carbon Dioxide, Carbon Monoxide, Nitric Oxide, Nitrogen Dioxide, Sulfur Dioxide, Nitrous Oxide, Hydrogen Chloride, Ammonia, Methane, Propane, Butane, Ethane, Ethanol, Ethylene, Propylene, Toluene, Acetylene, Chloroform, Dichloroethylene, Ethyl Benzene, Methyl Ethyl Ketone, Formaldehyde, Sulfur Hexafluoride, Phosgene, Vinyl Chloride, R134A
Adaptability
Yes; manufacturer can add new targets to detector
Sample Introduction
Vapor/Gas;
Sensitivity/Detection Limits
ppb; ppm; %
Start Up Time (From Cold Start To Sample Ready)
20 seconds to 5 minutes
Response Time (Sample Application To Output)
<5 minutes; 20 seconds to 5 minutes
Total Run Time
Continuous
Software Control
Rack-mount PC or laptop-controlled with OPUS software
Other Operational Parameters
10.2-meter optical path, Heated sample cell (50°or 191°C), 0.8 wave number (cm–1 ) resolution. No liquid nitrogen required.
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
IATA Shipping Restrictions
No